J: Air testing and standards - 202

(ACM) indicated mean asbestos levels ranging from 4*10 ® to 2.43*10"’ TEM f/cc (7*10"' to 4*10 ® PCM f/cc).

Asbestos concentrations in 41 schools that contained asbestos ranged from ND to 0.1 TEM f/cc (ND to 2*10-’ PCM f/cc), with an arithmetic mean of 0.03 TEM f/cc (5*10“* PCM f/cc). Another study reported average concentrations of airborne asbestos fibers > 5 pm in length of 8*10'® TEM f/cc and 2.2*10“* TEM f/cc in 43 non-school buildings and 73 school buildings, respectively (the 60:1 conversion factors would not apply to these data, since the TEM readings were already on fibers >5 pm in width, so they are likely to be more directly comparable to PCM results). In another study in 71 U.S. schools, the mean, the 95 percentile, and the maximum asbestos levels were 1.7*10“*, 1.4*10"’, and 2.3*10"’ PCM f/cc, respectively.

A study of 49 buildings in the United States reported mean asbestos fiber levels of 9.9*10'* PCM f/cc in buildings with no ACM, 5.9*10“* PCM f/cc in buildings with ACM in good condition, and 7.3*10“* PCM f/cc in buildings with damaged ACM.

In general, concentrations of asbestos in both indoor and outdoor settings and in both rural and urban settings appears to be less than, and by some studies, sometimes substantially less than, 3*10’’ f/cc on a PCM volumetric basis.

[Exposure and Human Health Evaluation of Airborne Pollution from the World Trade Center Disaster, External Review Draft, 10/02, National Center for Environmental Assessment, Office of Research and Development, EPA, Publication Nos. NCEA - W - 1395, or EPA/600/P-2/002A, http://www.epa.gov/ncea or http://oaspub.epa.gov/eims/eimscomm.getfile?p_download_id=36387 ]

EP?^eeion 2 believes that the AH ERA level is the normal air background level

As documented in my 3/11/02 memorandum, EPA Region 2 believes (believed) that the AHERA level was the background air level:

Region 2 mistakes 70 s/mm^ as a normal air “background” level

Regional Counsel for EPA's Region 2 explained his belief of the meaning of 70 s/mm’. He believes that it is a normal air background, and when the AHERA clearance test is run, the results of the test are COMPARED WITH the 70 s/mm’ “background" level;

These rules include what is commonly called a clearance test... The specified AHERA clearance test procedure includes, inter alia, a step in which air monitored in the affected space is compared with the specified “background” level of 70 structures per square millimeter (70 s/mm ^),

fMugdan, Walter E., Esq. (January 25, 2002) Environmental law issues raised by terrorist events in 2001. Speech before the NY Bar Association. Posted at www.NYenviroLAW.org J

This is wrong. There is no comparison going on at all with the results of the test and any purported background level of 70 s/mm^. Instead, the AHERA TEM clearance test

NYC-WTC_000251358

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000251358Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →