Asbestos sampling report, Tenants and Neighbors, NY

Machine-extracted title · confidence 39%

Asbestos sampling report for Tenants and Neighbors location in New York, prepared June 14, 2002.

NYC-WTC_000390668–000390670
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document 07/19/2002 10:27 FAX 2126197476 Tenant s&Nelsbbrs @03

105 Washington - Tenants and Neighbors!

Introduction At We request of Claude Rolo and Joe Heaphy of Tenants and Neighbors, asbestos sampling was conducted in the second floor offices of Tenants and Neighbors, located at 105 Washington Street in Manhattan. The survey included a visual inspection of the offices, and sampling surface dust for the presence of asbestos. Edward Olmsted, CIH, CSP performed the survey on May 31,2002. The purpose of this survey was to determine levels of asbestos contamination on carpets that may have been caused by file collqiae of We twin towers of the Trade Center. Asbestos is We most prevalent air contaminant produced during We collapse and as such it serves as a good surrogate for assessing exposure to oWer air contaminants. These fibers settle in the building as a dust and are likely to remain a problem unless proper cleaning is done. THE FINDINGS OF THE SURVEY INDICATE THAT IN SOME AREAS THE CARPET IS CONTAMINATED WITH ASBESTOS. Levels of asbestos ranged from non- detectable to 9,300 fibers per square centimeter. Background The World Trade Center (WTC) burned and collapsed on September 11, 2001. The buildings were constructed of cement, steel, glass, gypsum wadlboard, acoustical tile ceilings, $prayed-on insulation (asbestos-containing and non-asbestos types) and contained wood, plastic and metal furniture, computers and fixtures and paper products. Most of these materials were either physically destroyed (compressed, pulverized) or burned in the collapse of the building. This process gave rise to particulate matter ranging from a very' fine dust to larger sized, quicker settling particles. The dust settled out onto roofs and other surfaces of nearby buildings. The cleaning effort to remove die dust from these buildings has varied and is dependent upon the efforts of the building owner. In the 2"^ floor offices it was reported that the carpets and other surfaces in We office were cleaned by a contractor shortly after the collapse.

Methods Surface dust samples for tlie presence of asbestos were collected according to We method 5755-95 published by the American Society of Testing and Materials (ASTM). Thia involves drawing dust from a surface area of 100 square centimeters on a 0.8 micron mixed cellulose ester filter. Disposable paper 100 cm2 templates were used to collect We samples. A new clean template was used for each sample. The dust was collected using a personal sampling pump operated at 2 liters per minute. The filter is analyzed by transmissioh clectron mkrosKopy for asbestc^ fibeix. Afi of file samples were shipped overnight and analyzed by IATL. This lab is accredited through file New York State Department of HealW environmental lab accreditation program (ELAP).

Exposure Criteria The ASTM method is intended for guidance on examining dust contamination of building surfaces and as a general assessment of the building. There is no suggestion in the ASTM method that it can be used to assess general health risk from asbestos exposure, nor does it suggest that all building surfaces be maintained to the levels published in the Standard. The method is generally applicable for the estimation of.the concentration of asbestos fibers on surfaces starting from approximately 1000 fibers per square centunster

2

CITY_21MC100_002388587

NYC-WTC_000390669

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000390669Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000275438

EPA memorandum describing ultrasonication carpet dust test method for asbestos.

Similar indexed content

Compare copies and versions →