NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 51/105 DUANE STREET Block: 151 Lot: 1 BIN: 1001650 10-16 THOMAS ST1 TRIMBLE ST., TRIBECA TOWER
Document / 165 pages

DOH/DEP asbestos fact sheet draft, 105 Duane Street

Machine-extracted title · confidence 95%

Draft fact sheet from DOH and DEP addressing tenant concerns regarding asbestos fibers at 105 Duane Street.

NYC-WTC_000125845–000126009

Folder label: “105 DUANE STREET Block: 151 Lot: 1 BIN: 1001650 10-16 THOMAS ST1 TRIMBLE ST., TRIBECA TOWER

Page image
Scanned page image, NYC-WTC_000125917
OCR text

OCR status: ocr · source: ours

NYC 9/11 Public Portal Document RELATED MANAGMNT. LU. 1EL:212-540-1142 Dec 11 U1 14:30 NO.UU4 P.U0 The ASTM method is intended for guidance on examining dust contamination of building surfaces and is intended as & general assessment of the building. There is no suggestion in the ASTM method that it can be used to assest geneial bealth tisk from asbestos exposure, nor does it suggest that all building surfzoes be maintsined to the levels published in the standard. The method is generally applicable for the estimate of the concentration of asbestos fibers on furfaces starting from approximately 1000 fibers per square centimerer (f/cm2) On Docember 3" two surfaoe dust samples were taben from the 10ª floor to determine whether asbostos fibers were settled on surfaces. The results are reported in asbestos fibers per square centimeter of surface testod. The following summarizes the sample results: Sample C620204 sampled in living room from table top Result- 740 asbortos suructures per square centimeter Sample B1203-2 sampled from supply air diffuser in the 10ª floor public hallway Result - 350,000 asbestos structures per square centinteter The supply air grille in the ballway was found to have elevated levcla of asbestos fibert well above the recommended limit of 1000 structures per square centimeter. This suggests that the ventilation system was contaminiated by asbestos when the building collapsed The duct system should be eleaned by e professional duct cleaning company using vacuum and cleaning equipmept designed for asbestos decontamination. Sincerely, Elmrud geimts Edward Olmsied 12/11/01 TUE 14:08 (TX/RX NO 8850] 12003 NYC-WTC_000125917

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000125917Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →