ATTACHMENT 2
WTC Indoor Air Monitoring - Sampling and Analytical Procedures
Analytical
Media Pampling Points Sampling Method Proposed Sampling Vulnerability/Practicality Analytical Method Proposed
Parameters
Carpels, fabric furniture or
Settled drape'7 in areas of activity This is a micro vacuuming method. Three collocated samples will
Dust (living rooms, family Asbestos ASTM D 5755-95 ASTM D 5755-95
be collected from each location.
Porous rooms)
Soft
surfaces Lead ASTM E 1973-99 ■This is a micro vacuuming method. Three collocated samples will
be collected from each location. SW-846 601 OB
Hn'i/.nntal surfaces of
lab'ns or counters and
Asbestos ASTM D 6480-99 Wipe Samples ASTM D 6480-99 (wipe)
barn 'iQQrs, ceilings and
walls ip areas of activitv
r'i-inq rooms, family
rooms) Lead ASTM E 1728 Wipe Samples SW-846 601 OB
Settled
Dust
Non-porou Dioxins ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8290
s Hard
surfaces PAHs ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8270C
Silica ASTM E 1728** Wipe Samples NIOSH 7500 (XRD)
MMVF ASTM D 6480-99 Samples will be combined with the asbestos sampling. EMSL MSD.0300
fl'nas of known activity Air pump operated at lOL/min for 8 hours to achieve the COPC PCM NIOSH 7400 followed by TEM AHERA
Asbestos -^lOSK-7400
r'iving rooms, family
rooms)----------
□AI V pi n- ^i^erated atwkgroup detection limits
lOL/min for 8 hours to achieve the COPC
method.
;^NIOSi4/30o\
Leac SW-846 6010B
wkgroup detection limits
c TBI^e^in^-s^mi^l^dnie-
PAHs requirements and to account for Pilot clean-up study only SW-846 8270
break through on the cassettes.
Indoor Air
TBD Pending sample volume
Pilot clean-up study only. Availability of sample cassettes for
Dioxins requirements and to account for SW-846 8290
dioxins analysis is questionable. Apparently the supply is low.
break through on the cassettes.
n
Air pump operated at 2.5L/min for 8 hours to achieve the COPC
Silica NIOSH 7500 NIOSH 7500 (XRD)
wkgroup detection limits
Assumed that it behaves the same as asbestos, samples will be
S MMVF NIOSH 7400 EMSL MSD.0300
n combined with the asbestos sampling.
o
o NOTE: All samples 'cassettes and wipes) will be preweighed by the laboratory or supplier prior to sample collection. After sample collection and upon receipt of the samples by the laboratory, the laboratory will weigh
I the sample wipe c' cassette prior to performing the analysis. This may change depending upon the availability of preweighed materials. May collect samples for total dust
o
** Silica will be collected as a dust samples as is Lead. This was decided since pulverized silica would be particulate like and not fiber like as with asbestos and MMVF.
bO
bO
cn