NYC-WTC_000318755
Background report on asbestos and related contaminants for WTC environment, 1987.
27 shared non-person entities · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Background study draft on asbestos in schools related to WTC, March 2003.
NYC-WTC_000318678–000318754OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
41840 Federal Register / Vol. 52, No. 210 / Friday, October 30, 1987 / Rules and Regulations
thin fibers found at abatement sites. (length to width) of 5.1 or larger is commenters, particularly union groups, EPA research data has shown that PCM defined as a fiber. This represents a advised the Agency to increase worker is often inadequate for post-abatement change in the previous EPA proposed protection standards and alter the monitoring of airborne asbestos. These TEM methodologies which examine definition and requirements for small- data indicate that sites which were fibers with aspect ratios of 3:1 and scale, short-duration projects (as shown to be clean with PCM data were above: it follows the direction set by defined by Appendix B to Subpart E) found by TEM data to be still NIOSH in proposing modified counting prescribed by the Occupational Safety contaminated. Therefore, reoccupancy rules in the 7400 method. It is consistent and Health Administration's (OSHA's) of sites initially cleared by PCM, and with the panel of microscopists’ and EPA's relevant worker protection thus, assumed to have been adequately observations that asbestos structures regulations. In particular, comments cleaned, may in fact result in exposures have aspect ratios equal to and greater focused on permissible exposure limits to asbestos. than 5:1 whereas the majority of (PEL), the allowance of historical air SEM, for purposes of this rulemaking, . nonasbestos structures, minerals and' monitoring data, respiratory protection, was determined to be inadequate for particles, for example, gypsum, have and the practice of glove bag removal. building clearance for the following aspect ratios of less than 5:1. Analysis of Other commenters recommended no reasons: (1) Currently available these nonasbestos structures tends to change, citing OSHA’s primacy in this methodologies are not validated for the comprise a large portion of the time area. analysis of asbestos fibers: (2) SEM is required for sample analysis. EPA This final regulation, through the limited in its ability to identify the believes that further research is needed provisions of the EPA worker protection crystalline structure of a particular fiber. to justify the extension of aspect ratio to rule, extends coverage already in place (SEM analysis-is therefore confined to 10:1. Consequently, for the purpose of for O&M workers in private schools identification of structures by elemental TEM building clearance, fibers must under the OSHA construction standard composition and morphology): (3) recent have an aspect ratio of al least 5:1. to public sector O&M workers now studies conducted by NBS have 8. Phase-in period for TEM. Several unprotected in schools. This OSHA evaluated several types of scanning commenters asked that the phase-in standard also includes Appendix B of electron microscopes and the variability period for requiring TEM analysis be this rule. LEAs may implement the between these instruments. (NBS has lengthened, abbreviated, or eliminated provisions of Appendix B of the rule found the image contrast of the altogether. EPA believes the 3-year instead of the full scope of the EPA/ microscopes is difficult to standardize phase-in period for requiring TEM for all OSHA worker protection regulation between individual scanning electron but the smallest abatement jobs allows when they conduct small-scale, short- microscopes): and (4) currently no commercial laboratories the necessary duration activities (all of which are laboratory accreditation program exists time to purchase and set up additional presumed to exceed the action levefof for accrediting SEM laboratories. EPA is TEM instruments. In December 1987, 0.1 f/cm ’). aware of two methodologies for SEM: a estimates developed by EPA’s Office of The Agency maintains that OSHA is draft method currently in its initial Research and Development (ORD) the most appropriate Federal agency for review by the American Society for indicated that there were approximately determining worker protection policy. 82 commercial laboratories in the Testing and Materials (ASTM) and an As noted in the preamble to the country which advertised the ability to Asbestos International Association proposed rule, EPA believes that perform TEM analysis on airborne (AlA) protocol. Neither method has been OSHA’s recently completed worker asbestos samples. Testimony received validated. Additionally. NBS has protection rulemaking, a lengthy and during the August 25 and 26 public determined that the AlA method has detailed process focused specifically on hearings for this rulemaking as well as inherent difficulty when examining such issues, is as appropriate to school information gathered by EPA staff, certain types of asbestos. O&M workers via the EPA worker indicate that many laboratories ! Currently, a laboratory accreditation intended to purchase additional TEM protection rule as it is to other private i program is in development for TEM by equipment. In addition, several sector O&M workers, EPA continues in I NBS. Additionally, the AIHA PAT Program evaluates laboratories conducting PCM analyses. The NBS has laboratories own more than one transmission electron microscope. EPA believes that an increased this belief and no commenters have indicated substantive reasons why the OSHA protections should not be i unconditionally stated that it will not demand for TEM instruments will drive followed. formulate a laboratory accreditation the supply of instruments, and has Therefore, the Agency does not intend program for SEM based on existing stipulated the 3-year phase-in to allow to reassess the OSHA determination methodologies. Until suitable commercial laboratories time to react to with respect to issues such as PEL, the methodologies are developed, EPA will the increased demand. The Agency use of historical air monitoring data, continue to monitor and investigate the believes a shorter phase-in period, or respiratory protection, and the progress of SEM methodologies and requiring the immediate use of TE.M for allowance of glove bag removal. EPA I research for asbestos analysis. New all jobs would create a substantial will, however, change the provisions of I developments in SEM technology may burden on schools and laboratories. The its worker protection rule (and hence, allow SEM to be considered as an delay to clear abatement jobs and the this regulation) to conform with any acceptable asbestos measurement tool high cost associated with TEM analysis modifications subsequently adopted by in the future. for relatively small jobs would be OSHA. Regarding the use of TEM, several burdensome. EPA has consequently Finally, with regard to the definition commenters suggested that the aspect decided to retain the length and type of of "small-scale, short-duration" ratio (length to width) should be phase-in described in the proposed rule. activities, the Agency provides further extended to 10:1, For the purpose of clarification of the OSHA definition in TEM measurement by the methods in H. Operations and Mainienance and zXppendix B to Subpart E by adding five Appendix A, any elongated particle Worker Protection additional points which may be used to having a minimum length of 0.5 /xm, 1. Worker protection ar i "small- define such projects. EPA believes these parallel sides, and an aspect ratio scaie-short-duration”act 'it' ■ . Several aiiditional considerations are instructive
NYC-WTC_000318693
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000318755
Background report on asbestos and related contaminants for WTC environment, 1987.
27 shared non-person entities · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000449399
EPA Part 763 asbestos SOP excerpt with subparts and scope.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000451982
Chain-of-custody and SOP excerpt focusing on asbestos validation and PCB spiking.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434918
Continuation of the asbestos validation SOP text with definitions and scope.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445234
EPA Part 763 subpart I excerpt regarding asbestos, testing parameters and definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452898
Chain-of-custody excerpt referencing Part 763 asbestos procedures and compliance.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433711
Page from Part 763 asbestos standard; references to testing and enforcement sections.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445985
Chain-of-custody excerpt referencing Part 763 sections and regulatory definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435395
Part 763 Subpart text related to asbestos standards and testing definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438164
EPA SOP excerpts and references for asbestos validation and inspections.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442707
Pallet of Part 763 asbestos-related standard references and definitions.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000434667
Environmental protection document detailing Part 763 asbestos definitions and related sections.
27 shared non-person entities · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000318755
Background report on asbestos and related contaminants for WTC environment, 1987.
Similarity score 0.974 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318755
Background report on asbestos and related contaminants for WTC environment, 1987.
Similarity score 0.967 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243169
Department memo referencing 9/11 toxic hazards at Ground Zero site.
Similarity score 0.959 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302884
AHERA TEM clearance criteria and measurement details for school asbestos abatement.
Similarity score 0.957 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140259
Memorandum detailing procedures for asbestos wipe sampling in Lower Manhattan and estimating associated cancer risks from dust exposure.
Similarity score 0.950 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318755
Background report on asbestos and related contaminants for WTC environment, 1987.
Similarity score 0.949 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000318755
Background report on asbestos and related contaminants for WTC environment, 1987.
Similar indexed content
NYC-WTC_000449399
EPA Part 763 asbestos SOP excerpt with subparts and scope.
Similar indexed content
NYC-WTC_000451982
Chain-of-custody and SOP excerpt focusing on asbestos validation and PCB spiking.
Similar indexed content
NYC-WTC_000434918
Continuation of the asbestos validation SOP text with definitions and scope.
Similar indexed content
NYC-WTC_000445234
EPA Part 763 subpart I excerpt regarding asbestos, testing parameters and definitions.
Similar indexed content