NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 191 pages

Ground Zero WTC toxic hazards memo, 2002

Machine-extracted title · confidence 38%

Department memo referencing 9/11 toxic hazards at Ground Zero site.

NYC-WTC_000243169–000243359
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

microscope. The Clean Air Act, similarly, requires the use of TEM to determine whether wastes are free of asbestos, and OSHA recommends TEM or SEM for settled dust, although it requires only the PLM method for air sampling under its “permissible exposure limit” for a healthy worker on an 8-hour work shift, 40 hours per week.' The TEM method identifies smaller fibers, but it also more carefully distinguishes other fibers from asbestos so that it avoids overestimating the presence of asbestos. Consequently, the TEM method will give higher readings of asbestos if most of the fibers are actually asbestos and a significant fi-action of the fibers are smaller than 0.5 micrometers.

Other federal agencies used the TEM method to test the WTC dust. The federal ATSDR used the TEM method to further test the settled dust in its joint study with the City of residential contamination whenever the PLM method did not detect asbestos above one percent - which was all the time. Of a total of 97 samples, taken outdoors and indoors, PLM testing found no asbestos at all, but TEM testing found asbestos in 22 percent of the samples.'” Indeed, even the federal General Services Administration used the more sensitive TEM method in EPA’s own office building at 290 Broadway. It found asbestos levels that indicated a need for abatement. A Freedom of Information Act request by the New York Environmental Law & Justice Project revealed that the General Services Administration ’s TEM tests of five dust samples collected on September 14, 2001 - two collected outside the building entrance and three inside the lobby - found chrysotile asbestos, as did one of the air samples taken in the building lobby that day.’”

Interestingly, EPA did not wait for the General Services Administration ’s TEM test results to take action. EPA cleaned its lobby using high efficiency particulate air filter (“HEPA”) vacuum trucks.’” EPA has since stated that it removed the dust before it received those test results, simply because the dust was visible and because other PLM tests of WTC dust had “more than adequately indicated the widespread presence of asbestos in the dust.” It further asserted that it “took a blanket approach and removed all dust and debris regardless of whether sampling results indicated that the material contained asbestos.”’”

59 Fed. Reg. 38970 (Aug. 1, 1994), pursuant to analysis of air samples for asbestos under the Asbestos Hazard Emergency Response Act (Title II of the Toxic Substance Control Act 15 U.S.C. §§ 2641-2654); 40 CFR § 763 (EPA Asbestos Hazard Emergency Response Act regulations requiring analysis by TEM). “*’40 CFR § 61.155 (NESHAP) and 59 Fed. Reg. 542; (OSHA) 29 CFR § 1926.110a (App. A). ''** 29 CFR § 1926.1 101 (OSHA) (analysis by PLM, not TEM, and fibers shorter than 5 micrometers are not counted). 14Q Bruce Lippy, et al. (1989). Jenkins Memorandum Dec. 19, 2001, pp. 10 and 15-16. '5” T TSDR and Cily Health Department Residential Dust Study 2002, pp. 3 and 57. '5' See Stratus Corporation, “Asbestos Emergency Monitoring Report at 290 Broadway after the World Trade Center Disaster, Final Report" (Oct. 5, 2001 )(< http:.; www .nvenvirolaw.org/PDF 'EP.A-FOIL-scaniiedOii-2- 27-02.pdf >), Table 1. EPA did not release this information to the public until after a January 3, 2002 Freedom of Information Act request by the New York Environmental Law & Justice Project. '5’ Stratus Corporation, supra; Jenkins Memorandum 2002, pp. 36 and 39-40. ’5’ See “Responses to Questions posed by the St. Louis Post Dispatch (Mar. 1,2002)(undated, no author identified); see also EPA Region 2, “response to March 4, 2002 Questions from U.S. Senate Environment and Public Works Committee, Subcommittee on Clean Air, Wetlands and Climate Change,” (hereafter, EPA Region 2 Response to Questions from Senate Environment and Public Works Committee) p. 7 (both documents provided in response to Sierra Club Freedom of Information request).

47

NYC-WTC_000243222

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000243222Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →