TJN-17-200E 02:0EP TO:12122360041 P:8^14

KAM CONSULTANTS 35-4(136th SIreeL Long Island City

J<an\ New York, 11106 Tel; (716)729-1997 Fax: {718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: GPS Environmental Consultants, Inc., 31 Trescott Path, Fort Salonga, New York, 11768 BUILDING ADDRESS: 222 Broadway, Manhattan - 23rd,16th,I2th, 10th,3ril Floors PROJECT#: Client Sample ID# 23-01 19-02 16-03 16-04 12-05 Lab Sample ID# : 020516C-I577 O2O516C-1578 020516C-1579 0205160-1380 020516C-1581 Sample Location North Side on West Side On Set South Side on South West South Side on Sei Back Roof Back Roof Set Back Roof Comer on Set Set Back Roof 23rd Floor 19ih Floor 16(h Floor Back Roof I6ih 12th Floor Floor Homogeneity Yes Yes Yes Yes Yes Sample Description Wipe Wipe Wipe Wipe Wipe

Color: Wh Wh Wh Wh Wh Texture: Mixed Mixed Mixed Mixed Mixed Sample Treatment. None None None None None

Asbestos Present: (Type & Percent) ND ND ND ND <1%CHR Total Percent A.sbestos: 0% 0% O’/o O’/o <1%

Other Fibr. Mat, (Ty pe & PerceniT <1%FBOL 1%SYNTII <1%CELL <l’/oCELL 0%

Non Fibr Mat (Percent! >99% 99% >99% >99% >99% Date Received: 3/16/02 Date oF Analysis 5/16/02 Dale of Report 5/17/02

Analyst: Lab Manager: RoodyLouiZ' David Chen * Analvsis of samples is performed by PolarizcpKtight Microscopy (PLM) - Point Countino Method (,RPA 600/M4-82-020) / “ * Analvlical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM IS not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound malenals Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbcslos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested * The certificate of report shall not be reproduced w ithout the written approval of the laboratory ’ Ure report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government WS-DOH ELAr/f/1273 N/ST-NV7.AP # 102047 AIHA 0: 100269

Page 1 of 2

CITY_DEP_WORBY_CANNATA_SUBP_000007213

NYC-WTC_000306467

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000306467Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →