NYC 9/11 Public Portal Document
TJN-17-200E 02:0EP TO:12122360041 P:8^14
KAM CONSULTANTS
35-4(136th SIreeL
Long Island City
J<an\ New York, 11106
Tel; (716)729-1997
Fax: {718)729-1876
BULK SAMPLE ANALYSIS REPORT
CLIENT: GPS Environmental Consultants, Inc., 31 Trescott Path, Fort Salonga, New York, 11768
BUILDING ADDRESS: 222 Broadway, Manhattan - 23rd,16th,I2th, 10th,3ril Floors
PROJECT#:
Client Sample ID# 23-01 19-02 16-03 16-04 12-05
Lab Sample ID# : 020516C-I577 O2O516C-1578 020516C-1579 0205160-1380 020516C-1581
Sample Location North Side on West Side On Set South Side on South West South Side on
Sei Back Roof Back Roof Set Back Roof Comer on Set Set Back Roof
23rd Floor 19ih Floor 16(h Floor Back Roof I6ih 12th Floor
Floor
Homogeneity Yes Yes Yes Yes Yes
Sample Description Wipe Wipe Wipe Wipe Wipe
Color: Wh Wh Wh Wh Wh
Texture: Mixed Mixed Mixed Mixed Mixed
Sample Treatment. None None None None None
Asbestos Present:
(Type & Percent) ND ND ND ND <1%CHR
Total Percent
A.sbestos: 0% 0% O’/o O’/o <1%
Other Fibr. Mat,
(Ty pe & PerceniT <1%FBOL 1%SYNTII <1%CELL <l’/oCELL 0%
Non Fibr Mat
(Percent! >99% 99% >99% >99% >99%
Date Received: 3/16/02
Date oF Analysis 5/16/02
Dale of Report 5/17/02
Analyst: Lab Manager:
RoodyLouiZ' David Chen
* Analvsis of samples is performed by PolarizcpKtight Microscopy (PLM) - Point Countino Method
(,RPA 600/M4-82-020) / “
* Analvlical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope
(MEIJI ML-POL-Serial # 88034)
* PLM IS not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically
bound malenals Quantitative transmission electron microscopy is currently the only method that can be used
to determine if this material can be considered or treated as non-asbcslos-containing
* Samples will be stored for ninety (90) days and then returned to the client upon request
* The results relate only to the items calibrated or tested
* The certificate of report shall not be reproduced w ithout the written approval of the laboratory
’ Ure report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government
WS-DOH ELAr/f/1273 N/ST-NV7.AP # 102047 AIHA 0: 100269
Page 1 of 2
CITY_DEP_WORBY_CANNATA_SUBP_000007213
NYC-WTC_000306467