NYC 9/11 Public Portal Document
JUN-17-2002 02:02P FROM: TO:12122360041 P:8'14
KAM CONSULTANTS
35-40 36th Street
Long Island City
/~ New York ,1f106
Q Tel: (718)729 -1991
Fax: (718) 729.1876
BULK SAMPLE ANALYSIS REPORT
CLIENT: GPS Environmental Consultants, Inc., 31 Trescott Path, Fort Salonga, New York, 11768
BUILDING ADDRESS: 222 Broadway, Manhattan - 23rd,16th,12th, 10th,3rd Floors
PROJECT#:
Client Sample ID# 23-01 19-02 16-03 16-04 12-05
Lab Sample ID# . 020516C-1577 020516C-1578 020516C-1579 020516C-1580 020516C-1581
Sample Location. North Side on West Side On Set South Side on South West South Side on
Set Back Roof Back Roof Set Back Roof Corner on Set Set Back Roof
23rd Floor 19th Floor 16th Floor Back Roof 16th 12th Floor
Floor
Homogeneity• Yes Yes Yes Yes Yes
Sample Description: Wipe Wipe Wipe Wipe Wipe
Color: Wh Wh Wh Wh Wh
Texture: Mixed Mixed Mixed Mixed Mixed
Sample Treatment: None None None None None
Asbestos Present:
(Type & Percent) ND ND ND ND <1°/oCHR
Total Percent
Asbestos: 0% 0% 0% 0% <1%
Other Fibr. Mat.
(Type& Percent) - <I%FBGL l%SYNTII <I%CELL <1%CELL 0%
Non Fihr Mat
(Percent): >99% 99% >99% >99% >99%
Date Received: 5/16/02
Date of Analysis: 5/16/02
Date of Report: 5/ 17/02
Analyst: -
Roody Lori
Lab Manager: '1) C -
David Chen
* Analysis of samples is performed by Polariz9fl.ight Microscopy (PLM) - Point Counting Method
(EPA 600/M4-82-020)
* Analytical equipments: Stereobinoeular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope
(MEIJI ML-POL-Serial # 88034)
* PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically
bound materials. Quantitative transmission electron microscopy is currently the only method that can be used
to determine if this material can be considered or treated as non-asbestos-containing
* Samples will be stored for ninety (90) days and then returned to the client upon request
* The results relate only to the items calibrated or tested.
* The certificate of report shall not be reproduced without the Mitten approval of the laboratory
* The report must not be used by the client to claim endorsement by NVLAP or any agency ofthe US Government.