NYC 9/11 Public Portal Document MAY-13-2002 04:12P FROM: TO:121242201B4 P:4/6 KAMCONSU S11(TS 35.4036thStreet Lang Island t 1ty NewYark1m05 Tel: (n8t7294991 Fall: (?18129.1876

BULK SAMPLE ANALYSIS REPORT CLIENT: GPS Environmental Consultants, Inc., 31 Trescott Path, Fort Salonga, New York, 11768 BUILDING ADDRESS: 105 Broad Street, Manhattan, New York - Building Facade PROJECT#: Client Sample ID#: 12 Lab Sample ID#: 020419A-1654 Sample Location: Water Street Entrance Door Homogeneity: Yes Sample Description: Wipe

Color. Wh Texture: Mixed Sample Treatment: None

Asbestos Present (Type & Percent) ND Total Percent Asbestos; - 0% Other Fibr. Mat. (Type & Percent): <I %FBGL 5%SYNTH Non Fibr. Mat. (Percent): 94% Date Received: 4/19/02 Date of Analysis: 4/22/02 Date of Report: 4/22/02

Analyst: - Lab Manager: Roody LoujV David Chen * Analysis of samples is performed by dlarized Light Microscopy (PLM) - Point Counting Method (EPA 600(14.82-020) * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930). Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consittently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP # 11273 NIST--NVLAP # 102047 A!HA #: 100269

Page 3 of 3

NYC-WTC 000105449

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000105449Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →