NYC 9/11 Public Portal Document MHY-1.5-i&i1 1d4:1ifi' I-RUM: TO:1212422184 P:2'6 KAY ONSULTAIITS 36.4036td Street 14119 IslandCity N oi6 Tel:(118)129.1991 Fax:(718'129.1676

BULK SAMPLE ANALYSIS REPORT CLIENT: GPS Environmental Consultants, Inc., 31 Trescott Path, Fort Salonga, New York, 11768 BUILDING ADDRESS: 105 Broad Street, Manhattan, New York - Building Facade PROJECT#: Client Sample ID# : 1 2 3 4 5 Lab Sample ID# : 020419A-1644 020419A-1645 020419A-1646 020419A-1647 020419A-1648

Sample Location: Window Broad Window Broad Window Broad Window Water Window Water Street Side Street Side Street Side Street Side Street Side

Homogeneity: Yes Yes Yes Yes Yes

Sample Description: Wipe Wipe Wipe Wipe Wipe

Color. Wh'Blk Wh/Blk Bik Blk Whh'Brn

Texture: Mixed Mixed Mixed Mixed Mixed

Sample Treatment: None None None None None

Asbestos Present: (Type & Percent) ND ND ND ND ND Total Percent Asbestos: 0% 0% 0% 0% 0%

Other Fibr. Mai. (Type& Percent): <1%CELL <1%CELL 3%CELL 5%CELL 3%CELL 3%SYNTH S%SYNTH 2%SYNTH 2%SYNTH 5%SYNTH Non Fibr. Mat. (Percent): 96% 94% 95% 93% 92% Date Received: 4/19/02 Date of Analysis: 4/22102 Date of Report: 4/22/02

Analyst Lab Manager: Roody is David Chen * Analysis of samples is performed Polarized Light Microscopy (PLM) - Point Counting Method (EPA 6001M4-82-020) * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial 0 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverines and similar non-friable organically bound materials. Ouantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. * The report must not be used by the client to claim endorsement by NVLAP or any agency of the US Government. NYS-DOH FLAP # 11273 NIST-NVLAP # 102047 AIHA #: 100269

Page 1 of 3

NYC-WTC 000105447

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000105447Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →