NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.3
☕ Buy me a coffee
← Document results/DEP Box 37/105 BROAD STREET; Block: 7; Lot: 31; BIN: 1000012; 22 Water Street
Document / 15 pages

Letter re: 105 Broad Street DEP program exclusion, May 2002

Machine-extracted title · confidence 95%

Property owner requests exclusion of 105 Broad Street from the DEP cleaning program based on building characteristics.

NYC-WTC_000105444–000105458

Folder label: “105 BROAD STREET; Block: 7; Lot: 31; BIN: 1000012; 22 Water Street”

Page image
Scanned page image, NYC-WTC_000105448
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document MAY-13-2002 04:12P FROM: TO:12124220184 P:3/6 KAM CQNSULTANIS 35.4036thStrat UPI lslead CITY LtiiAi Newyork itm Tel: (It8)TS91w _Fax:{Pl8~Tl9-1816

BULK SAMPLE ANALYSIS REPORT

CLIENT: GPS Environmental Consultants, Inc., 31 Trescott Path, Fort Salonga, New York, 11768 BUILDING ADDRESS: 105 Broad Street, Manhattan, New York - Building Facade PROJECT#: 8 9 10 11 Client Sample ID#: 6 020419A-1649 020419A-1650 020419A-1651 020419A-1652 020419A-1653 Lab Sample 1D#: Sample Location: Bldg. Facade Bldg. Facade Bldg. Facade Bldg Facade 105 Broad Broad Street Broad Street Water Street Water Street Street Ent. Side Side Side Side Door

Homogeneity: Yes Yes Yes Yes Yes

Sample Description: Wipe Wipe Wipe Wipe Wipe

Color. Wh Wh/Br Wh/Blk Wh Wh

Texture: Mixed Mixed Mixed Mixed Mixed

Sample Treatment: None None None None None

Asbestos Present: (Type & Percent) ND ND ND ND ND

Total Percent Asbestos: 0% 0% 0% 0% 0%

Other Fibr. Mat. 30%SYNTH 5%SYNTH <1%0FBGL 3%SYNTH 5%SYNTH (Type & Percent): <10/aCELL Non Fibr. Mat. (Percent): 70% 95% 980/0 97% 95% Date Received: 4/19/02 Date of Analysis: 4/22/02 Date of Report: 4/22/02

Analyst• t'N.t~y Lab Manager: t" 1 Roodv is David Chen • Analysis of samples is performed Polarized Light Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) * Analytical equipments: Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Serial # 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos-containing * Samples will be stored for ninety (90) days and then returned to the client upon request * The results relate only to the items calibrated or tested. The certificate of report shall not be reproduced without the written approval of the laboratory. Government. $ The report must not be used by the client to claim endorsement by NVLAP or any agency of the US NYS-DOM ELAP x111273 NIST-NYLAP # 102047 AIHA #: 100269

Page 2 of 3

NYC-WTC 000105448

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000105448Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →