Bulk sample analysis report, GPS 222 Broadway, 2002

Machine-extracted title · confidence 50%

Bulk sample analysis for 23rd-16th floors, sample IDs 23-01 to 16-05.

NYC-WTC_000306464–000306466
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

jN-:?-ee0E 02:01° fron: 10:12122360041

XAH CONSULTANTS 35-4036th Street Long Island City

J<am, Ne* York, 11106 Tel; (718)729-1997 Fax:(718)729-1876

BULK SAMPLE ANALYSIS REPORT CLIENT: GPS Environmental Consultants, Inc., 31 Trcscott Path, Fort Salonga, New 'York, 11768 BUILDING ADDRESS; 222 Broadway, Manhattan - 23r(l,16th,12th, 10th,3rd Floors PROJECT#: Client Sample ID# 23-01 23-02 23-03 16-04 16-05 Lab Sample O 020510B-1557 020516B-1558 020516D-1559 O2O516B-1560 020516B-1561 Sample Loeation; South Side on Center on Set South West Vi'cst Side on North West Set Back Roof Back Roof Comer Set Back Set Back Roof Comer on Set 23rd Floor 23 rd Floor Roof 23rd Floor 16th Floor Back Roof 16th Floor I lomogcneity. Yes Yes Yes Yes Yes

Sample Descriplion: N/A N/A N/A N/A N/A

Color Bm Bm Gi Gr Gr

Texture' Mixed Mixed Mixed Mixed Mixed

Sample Treatment: None None None None None

Asbestos Present: (.Type & Percent) ND <I%CHR 1,5%CHR <1%CHR <l%Ct{R Tdial Percent Asbestos: 0% <1% 1,5% <1% <1%

Other Fibr. Mat (Tvpe & Percent'): 70WBGL 90%FBGL 0% 0% 0% 1%CELL Non Fibr Mat. (.Percent): 29% >9% 98.5% >99% >99% Dale Received, 5/16/02 Date of Analysis 5/16/02 Dale of Report 5/17/02

Analyst: Lab Manager: ctM Roody Loi^ David Chen * Analysis of samples is performed by Polaiiada Licht Microscopy (PLM) - Point Counting Method (EPA 600/M4-82-020) < * AitaMical equipments Slereobinocuiar microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope (MEIJI ML-POL-Scrial# 88034) * PLM is not consistently reliable in detecting asbestos in floor coverings and similar non-frnible oigamcally bound materials Quantitative transmission electron microscopy is currently the only method that can be used to determine if this malenat can be considered or treated as non-asbestos-containing * Samples will be stored tor ninety (90) days and then relumed to the client upon request * Hie results relate only to the items calibrated or tested. * The certificate of report shall not be reproduced without the written approval of the laboratory. ' The report must not be used by the client Io claim endorsement by NVLAP or any agency of the US Government. NYS-DOH ELAP# 11273 NlSr-WLAP^mO47 AJffA #: 160269

Page 1 of 3

CITY_DEP_WORBY_CANNATA_SUBP_000007209

NYC-WTC_000306464

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000306464Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →