NYC 9/11 Public Portal Document
'UN-1.7"2002 02:02P -RON:
TO:12122360041 P:g-'14
KAM CONSULTANTS
35-40 36th Street
Leng Island City
J<an\ New York, 11106
Tei; !718)729-1997
Fax: 1718)729-1876
BULK SAMPLE .ANALYSIS REPORT
CLIENT: GPS Environmental Consultants, Inc., 31 Trescott Path, Fort Salonga, New York, 11768
BUILDING ADDRESS: 222 Broadway, Manhattan - 23rd,16th,12th, 10th,3rd Floors
PROJECT#:
Client Sample ID# : 10-06 10-07 3-08 3-09
Lab Sample ID# : 020516C-1582 020516C-1383 020516C-1584 020516C-1585
Sample Location: Facing Fulton North Side on West Comer Facing Ann
Street Center Set Back Roof on Set Hack Street Center
10th Floor Roof J rd Floor 3rd Floor
Homogeneily: Yes Yes Yes Yes
Sample Description: Wipe Wipe Wipe Wipe
Color Wh Wh Wh Wh
Texture: Mixed Mixed Mixed Mixed
Sample Treatment: None None None None
Asbestos Present
(.Type & Percent) <1%CHR ND ND ND
Total Percent
Asbestos: <1% 0% 0% 0%
Other Fibr Mat.
iType & Percent! 0% 3%FBGL 2%CELL <1%SYNTH
Non Fibr Mat.
(Percent). >99% 97% 98% >99%
Date Received 5/16/02
Date of Analysis 5/16/02
Date of Report: 5/17/02
f/
Analyst: Lab Manager;
Roody Lpdis David Chen
* Analysis of samples is performed bv Polafized Lieht Microscopy (.PLM) - Point Counting Method
(EPA 600/M4-82-020) ' ‘
* Analytical equipments Stereobinocular microscope (MEIJI EMT-Serial # 25930), Polarized Light Microscope
(MEiJI ML-POL-Senal # 88034)
* PLM is not consistently reliable in detecting asbestos in floor covenngs and similar non-friable organically
bound maienals. Quantitative transmission electron microscopy is currently the only method that can be used
to determine if this material can be considered or treated a.s non-osbestos-containing
* Samples will be stored for ninety' (90) days and then returned to the client upon request
* The results relate only to the items calibrated or tested.
* The cenificate of report shall not be reproduced without the written approval of the laboratory.
The report must not be used by the client to claim endorsement by NV LAP or any agency of the US Government
/VYS-DOH ELAP#11273 NIST-NnAP # 1(12047 AlHA #.■ 100269
Page 2 of 2
CITY_DEP_WORBY_CANNATA_SUBP_000007214
NYC-WTC_000306468
OCR can misread numbers and units. Confirm readings against the page image before using them.