NYC 9/11 Public Portal Document
U.S. Environmental Protection Agency (wn>w.epa.gov)
Air / Bulk / Wipe/ W'ater Sampling Situation Report
Monday, October 22, 2001 (2:00 PM)
Ambient Air Sampling Locations
NYC / ER (Oct 19) - Particulate Monitoring (PM2.5)
o Pace University (Site 1) - 24-hr average concentration for this period was 26.44 ug/m\
o Manhattan Boro Community College (Site 2) - 24-hour average concentration for this
period was 18.37 ug/m\
O Coast Guard Building - Battery Park (Site 3) - 24-hour average concentrations for this
period was 15.43 ug/m^.
o All readings below the National Ambient Air Quality Standard for PM2.5 (65 ug/m^).
NYC / ER (Oct 20) - Particulate Monitoring (PM2.5)
o Pace Llniversity (Site 1) - 24-hr average concentration for this period was 27.77 ug/m^.
o Manhattan Boro Community College (Site 2) - 24-hour average concentration for this
period was 24.82 ug/m''.
Q Coast Guard Building - Battery Park (Site 3) - 24-hour average concentrations for this
period was 20.22 ug/nt\
O All readings below the National Ambient Air Quality Standard for PM2.5 (65 ug/m'’).
NYC / ER (Oct 20) - Particulate Monitoring (Dataram)
O Particulate levels noted at three locations (Stations L, N, R) were below the OSHA TWA.
O Instruments operated approximately 6 hours.
O Station L values ranged from 59.1 to 124.2 ug/m3 with an average of 110.7 ugz'm3.
O Station N values ranged from 0 to 139.5 ug/m3 with an average of 116.9 ug/m3.
O Station R values ranged from 58.2 to 144.7 ug/m3 with an average of 121.6 ug/m3.
NYC / ER (Oct 21) - Particulate Monitoring (Dataram)
o Particulate levels noted at three locations (Stations L, N, R) were below the OSIIA TWA.
o Instruments operated approximately 3 A hours.
o Station L values ranged from 58.2 to 98.5 ug/m3 with an average of 83.8 ug/m3.
o Station N values ranged from 0 to 101.1 ug/m3 with an average of 86.1 ug/m3.
o Station R values ranged from 51.2 to 79.3 ug/m3 with an average of 67.7 ug/m3.
NYC / ER (Oct 19) - Volatile organics (TAGA)
O Benzene exceeded OSHA TWA PEL (1 ppm) at one location on the debris pile in the
plume at ground level.
NYC / ER (Oct 20) - Volatile organics (TAGA)
O Benzene exceeded OSHA TWA PEL (I ppm) at one location on the debris pile in the
plume at ground level.
NYC / ER (Oct 21) - Volatile organics (TAGA)
O Benzene exceeded OSHA TWA PEL (1 ppm) at one location on the debris pile in the
plume at ground level.
CITY_21MC100_004220067
NYC-WTC_000304158
OCR can misread numbers and units. Confirm readings against the page image before using them.