NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Particulate monitoring, Dec 2001

Machine-extracted title · confidence 28%

Dec 29–30 2001 TEOM PM and particulate data; some site values provided.

NYC-WTC_000321220–000321221
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pagein Jessica Leighton - RA_sitrep01 -O2.wpd Me

U.S. Environmental Protection Agency (w’H’M’.e/ja.gov) Sampling Situation Report Wednesday, January 2, 2002

Ambient Air Sampling Locations

NYC / ER (Dec 29) - Particulate Monitoring (TEOM PM 2 b

o Park Row (Site 1) - 24-hr average concentration for this period was 13.78 ug/m\ o Chambers St./West St. (Site 2) - 24-hour average concentration for this period was 11.37 ug/m^. o Wall Street - 24-hour average concentrations for this period was 10.35 ug/nt^. o All readings below the National Ambient Air Quality Standard for PM2 2 (65 ug/m’). o Note: Monitoring at the Coast Guard Station has ended.

NYC / ER (Dec 29) - Particulate Monitoring (TEOM PMio)

o Wall Street - 24-hour average concentrations for this period was 18.69 ug/m^. o All readings below the National Ambient Air Quality Standard for PMio (150 ug/m’).

NYC / ER (Dec 30) - Particulate Monitoring (TEOM PM 2.5)

o Park Row (Site 1) - 24-hr average concentration for this period was 11.29 ug/m\ o Chambers St./West St. (Site 2) - 24-hour average concentration for this period was S. 74 ug/m\ o Wall Street - 24-hour average concentrations for this period was 8.87 ug/m\ o All readings below the National Ambient Air Quality Standard for PM2.5 (65 ug/m’).

NYC / ER (Dec 30) - Particulate Monitoring (TEOM PMio)

o Wall Street - 24-hour average concentrations for this period was 15.52 ug/m^. o All readings below the National Ambient Air Quality Standard for PMio (150 ug/m’).

NYC / ER (Dec 31) - Particulate Monitoring (Dataram)

o Particulate levels noted at three locations (Stations L, N, R) were below the OSHA TWA. o Instruments operated approximately 6 to 616 hours. o Station L values ranged from 4.4 to 2555.1 ug/m’ with an average of 30.1 ug/m’. o StationN values ranged from 8.0 to 125.8 ug/m’with an average of21.3 ug/m’. o Station R values ranged from 10.9 to 84.0 ug/m’ with an average of 25.4 ug/m’.

NYC / ER (January 1, 2002) - Particulate Monitoring (Dataram)

CITY_21MC100_002458799

NYC-WTC_000321220

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000321220Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000321202

Dec 2001 asbestos air sampling results; particulate monitoring noted and malfunctions listed.

Similar indexed content

NYC-WTC_000321215

Jan 1–3 2002 asbestos air sampling results; several samples not collected due to malfunctions.

Similar indexed content

NYC-WTC_000321191

Record of NYC/ER air sampling results for asbestos with mentions of equipment malfunctions.

Similar indexed content

Compare copies and versions →