Air sampling form, PM2.5 readings, Oct 2001

Machine-extracted title · confidence 54%

EPA/DOH PM2.5 particulate monitoring results across multiple site readings at Battery Park and WTC area.

NYC-WTC_000357916–000357917
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

U.S. Environmental Protection Agency (www.epa.gov) Air / Bulk / Wipe/ Water Sampling Situation Report Monday, October 22, 2001 (2:00 PM)

Ambient Air Sampling Locations

NYC / ER (Oct 19) - Particulate Monitoring (PM2.5)

□ Pace University (Site 1) - 24-hr average concentration for this period was 26.44 ug/m\ O Manhattan Boro Comnninitv College (Site 2) - 24-hour average concentration for this period was 18.37 ug/m\ O Coast Guard Building - Battery Park (Site 3) - 24-hour average concentrations for this period was 15.43 ug/tn\ O All readings below the National Ambient Air Quality Standard for PM2.5 (65 ug/m^.

NYC / ER (Oct 20) - Particulate Monitoring fPVh ))

o Pace University (Site 1) - 24-hr average concentration for this period was 27.77 ug/m\ o Manhattan Boro Cominunitv College (Site 2) - 24-hour average concentration for this period was 24.82 ug/m \ O Coast Guard Building - Battery Park (Site 3) - 24-hour average concentrations for this periodwas2flr22«^^\ O All readings below the National Ambient Air Quality Standard for PM2.5 (65 ug/m’).

NYC / ER (Oct 20) - Particulate Monitoring (Dataram) o Particulate levels noted at three locations (Stations L, N, R) were below the OSHA TWA. o Instruments operated approximately 6 hours. o Station L values ranged from 59.1 to 124.2 ug/m3 with an average of 110,7 ug/m3. o Station N values ranged from 0 to 139.5 ug/m3 with an average of 116.9 ug'm3. o Station R values ranged from 58.2 to 144.7 ug/m3 with an average of 121.6 ug/m3.

NYC / ER (Oct 21) - Particulate Monitoring (Dataram) o Particulate levels noted at three locations (Stations L, N, R) were below the OSHA TWA. o Instruments operated approximately 314 hours. o Station L values ranged from 58.2 to 98.5 ug/m3 with an average of 83.8 ug/m3. o Station N values ranged from 0 to 101.1 ug/m3 with an average of 86.1 ug/m3. o Station R values ranged from 51.2 to 79.3 ug/m3 with an average of 67.7 ug/m3.

NYC / ER (Oct 19) - Volatile organics (TAGA)

O Benzene exceeded OSHA TWA PEL (1 ppm) at one location on the debris pile in the plume at ground level.

NYC / ER (Oct 20) - Volatile organics (TAGA)

O Benzene exceeded OSHA TWA PEL (1 ppm) at one location on the debris pile in the plume at ground level.

NYC / ER (Oct 21) - Volatile organics (TAGA)

O Benzene exceeded OSHA TWA PEL (1 ppm) at one location on the debris pile in the plume at ground level.

CITY_21MC100_009250463

NYC-WTC_000357916

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000357916Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

Air sampling locations, Oct 2001 · Box unavailable

NYC-WTC_000321273

EPA asbestos air sampling at NYC/ER and NJ/ER with most results below TEM AHERA; one location not sampled and one above standard noted.

6 shared non-person entities · 1 shared topics · similarity 0.971

machine-extracted · confidence unavailable · Check page ↗

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Air sampling locations, Oct 2001

NYC-WTC_000321273

EPA asbestos air sampling at NYC/ER and NJ/ER with most results below TEM AHERA; one location not sampled and one above standard noted.

Similar indexed content

Compare copies and versions →