NYC 9/11 Public Portal Document
!.
ButyPust Samples
NYC / ER (Oct 10) - Semi-volatile organic compounds (base neutral acid extractable)
O 2 dust samples obtained from rooftops in the vicinity of the WTC (22 Cortlandt. " fl.
and 600 Gateway Plaza, 34‘^ fl.) revealed elevated levels of polyaromatic hvdrocarbons
(PAHs).
O Both samples were above the EP.A Removal Action guidance levels (based on a 30-year
exposure) represented as Toxic Equivalency Factors (TEFs) for benzotalpyrene.
o Both samples were below the adjusted EP.A Removal Action guidance levels (based on a
1-year exposure) represented as Toxic Equivalency Factors (TEF.s) for benzol aipyrenc.
o Assuming the roofs have not been cleaned, limited potential exists for exposure due to-
location.
o Depending on the roofing materials used, the location (root) may have contributed
somewhat to the sample results.
o Dust samples previously collected on Sep 16 from street-level locations had significantly
lower PAH levels.
Direct Reading Instruments
NYC ' ER (Oct 19)
O Nothing of significance noted.
NYC / ER (Oct 20)
O Nothing of significance noted.
NYC/ER (Oct 21)
O Several readings noted above the carbon monoxide NAAQS (8 hr. average) of 9 ppm. 1
below the NAAQS (1 hr. average) of 35 ppm and the OSHA PEL ot 50 ppm.
Water
NYC / ER (Oct 5) - Total Petroleum Hydrocarbon Fingerprint/PCBs
O 1 water sample collected from the basement of 140 West St.
o The sample appeared to be indicative of a highly weathered fuel oil, most likely -4 fuel
oil.
O PCBs were not detected in the sample.
CITY_21MC100_004220068