ENyiRQNMENTAL TEL 5 212-83-7-8329 Jan 23’02 15:09 No .007 P.O?

Mr. Steve Thompson November 26,2001 Page 3 .

Arsenic, beryllium, cadmium, chromium, lead, and selenium results were below the detection limit of the analytical methods for 3 of the 4 samples collected and analyzed.

P"? cf tha samples had detectable concentrations of lead. The concentration of lead in this sample was 0.699 ug/m’, which was significantly below the OSHA PEL for lead of 50 ug/m’.

A copy of a spreadsheet summarizing laboratory data is attached.

Silica and Total Particulates

The following is a summary of the results of the silica and total particulate analyses:

« The calculated PELs for one of the silica samples was 9.6 mg/m’ (Corbett) and the other sample had less than the detection limit of silica (Konczynski). Results from this sample are not applicable to a calculated PEL.

The calculated TWAs for the two silica samples were 0.12 mg/m’ (sample collected from Corbett) and <0.027 mg/m’ (sample collected from Konczynski).

Both of the silica samples were significantly below their calculated OSHA PELS.

The 6 hour TWA for total particulates ranged from 0.307 mg/m’ to 1.013 mg/m’, which were significantly below the OSHA PEL Of 15 mg/m’.

A copy of a spreadsheet summarizing laboratory data is attached.

CONCLUSIONS

Asbestos

OSHA has an established PEL for asbestos of 0.1 f/cc measured as an 8-hour TWA, and an excursion limit of 1.0 f/cc measured over a 30-minute period. However, several sources have suggested that disease can be caused by exposure to asbestos at concentrations below the OSHA PEL. None of the samples collected in the time period covered by this report exceeded the OSHA PEL for either the TWA or the excursion limit.

-Petals

None of the metals analyzed were detected at concentrations near the OSHA PEL. Lead was detected in one sample, but not at concentrations that warrant concern. The NIOSH test method followed did not differentiate between soluble and insoluble chromium, and does not identify the valance state of the chromium As such, EE&G

CITY_21MC100_008110507

NYC-WTC_000289904

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000289904Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →