NYC 9/11 Public Portal Document
Mr. Bill Garibay
December 30, 2001
Page 2
Metals
Air samples were collected by drawing a known volume of air across a 37 mm mixed
cellulose ester filter, using battery-powered pumps. The pumps were calibrated and
secured to workers as described previously. Samples were sent to EMSL for analysis
by inductively coupled plasma (ICP) following NIOSH Method 7300. The laboratory
analyzed for six metals including: arsenic, beryllium, cadmium, total chromium, lead, and
selenium. Results were reporied as micrograms of each metal per cubic meter of air
(ug/m®). A total of two whole-shift sample.? were collected during the period of time
covered by this report.
Silica and Total Particles
Samples were collected by drawing a known volume of air across a 37 mm polyvinyl
chloride pre-weighted filter, using battery-powered pumps. The analysis of silica and
total particulates is conducted on the same filter. The pumps were calibrated and
secured to the workers Ps previously described. Samples were sent to EMSL, Samples
were first weighed to determine total particles, and were then analyzed by X-ray
diffraction microscopy following NIOSH Method 7500. Results were reported as
milligrams per cubic meter of air (mg/m’) for both parameters. Three whole-shift
samples were analyzed during the period of time covered by this report. OSHA does not
have a set PEL for silica. Rather, the PEL is based on the percent (%) of silica (SiOa)
present in the sample. The formula, presented in the OSHA "Z-3 Table" is as follows:
PEL= 30 mq/m^
%SiO2 +2
FINDINGS
Asbestos
The following is a summary of the results of the PCM analyses;
None of the calculated TWAs were above the OSHA PEL of 0.1 f/cc.
The TWAs ranged from 0.005 f/cc to O.0O6 f/cc.
A copy of Table 1 summarizing PCM laboratory data is attached
Metals
The following is a summary of the results of the metal analyses;
Both of the samples had detectable concentrations of total chromium.
The concenYation of total chromium in these samples were 0.630 ug/m^
and 0.574 ug/m\ which was significantly below the OSHA PEL for
chromium of 500 ug/m^.
The NIOSH test method followed did not differentiate between soluble
and insoluble chromium, and does not identify the valance state of the
chromium. As such, EE&G a.ssumed that all chromium detected was the
more toxic soluble form of the metal, and presented the more
conservative exposure limit of 500 ug/m”
ot’d 62:21 2002 12 iOO
CITY_21MC100_008110501
NYC-WTC_000289898
OCR can misread numbers and units. Confirm readings against the page image before using them.