Summary of Air Sample Data, Staten Island Landfill, 11/01

Machine-extracted title · confidence 42%

Summary of personal exposure air monitoring data collected for DSNY at the Staten Island landfill on 11/16/01.

NYC-WTC_000289902–000289905
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ENkAIRONMENTRL TEL:212-837-8329 Jan 23’02 15:09 No.007 P.06

Mr. Steve Thompson November 26, 2001 Page 2 .

A total of 15 whole-shift sample sets, and 14 excursion samples were collected during the period of time covered by this report.

Metals

Air samples were collected by drawing a known volume of air across a 37 mm mixed cellulose ester filter, using battery-powered pumps. The pumps were calibrated and secured to workers as described previously. Samples were sent to EMSL for analysis by inductively coupled plasma (ICP) following NIOSH Method 7300. The laboratory analyzed for six metals including; arsenic, beryllium, cadmium, total chromium, lead, and selenium. Results were reported as micrograms of each metal per cubic meter of air (ug/m’). A total of 4 whole-shift samples were collected during the period of time covered by this report,

Silica and Total Particles Samples were collected by drawing a known volume of air across a 37 mm polyvinyl chloride pre-weighted filter, using battery-powered pumps. The analysis of silica and total particulates i< fpnducted on the same filter. The pumps were calibrated and secured to the workers as previously described. Samples were sent to EMSL. Samples were first weighed to determine total particles, and were then analyzed by X-ray diffraction microscopy following NIOSH Method 7500 Results were reported as milligrams per cubic meter of air (mg/m®) for both parameters. A total of 2 whole-shift samples were collected during the period of time covered by this report. OSHA does not have a set PEL for silica. Rather, the PEL is based on the percent (%) of silica (SiOa) present in the sample. The formula, presented in the OSHA "2-3 Table" is as follows:

PEL= aoingArP %SiO2 +2 FINDINGS

The following is a summary of the results of the PCM analyses:

None of the calculated TWAs were above the OSHA PEL of 0.1 f/cc

None of the calculated short-term exposures were above the OSHA excursion limit of 1.0 f/cc.

Of the excursion samples collected, all 14 were below the detection limit of the test method.

A copy of a spreadsheet summarizing PCM laboratory data is attached.

Metals The following is a summary of the results of th© metal analyses:

CITY_21MC100_008110506

NYC-WTC_000289903

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000289903Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →