NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

Summary of air sample data, DSNY [name] Station, 12/20/01

Machine-extracted title · confidence 60%

Contractor summary of personal exposure air monitoring for DSNY debris handling.

NYC-WTC_000289897–000289900
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bill Garibay December 30, 2001 Page 3

A copy of Table 2 summarizing mstal laboratory data is attached.

Silica and Total Particulates

The following is a summary of the results of the silica and total particulate analyses

The three samples were below the detection limit of ths analytical method for silica. Since no silica was identified in these samples, a PEL could not bs calculated.

The total particulate data ranged from 0.031 ug.'m^ to 0.144 ug/m^, which is significantly below the PEL of 15 ug/m^

A copy of Table 3 summarizing laboratory data is attached.

CONCLUSIONS

Asbestos

OSHA has an established PEL for asbestos of 0.1 f/cc measured as an 8-hour TWA. However, several sources have suggested that disease can be caused by exposure to asbestos at concentrations below the OSHA PEL. None of the samples collected in the time period covered by this report exceeded the OSHA PEL. Although this data indicates that airborne asbestos fiber concentrations are below the OSHA PEL, they do not indicate an ''asbestos free" environment. Information from dust samples at the WTC site in Manhattan suggest that over 95% of the asbestos fibers detected were smaller than 0,25 micron in width, below the detection limit of the NIOSH PCM (7400) and TEM (7402) methods (Granger, et. al. Preliminary Health Hazard Assessment: World Trade Center Brief Communication: Technical Note, Submitted to American industrial Hygiene Association. October 2, 2001).

Metals

None of the metals analyzed were detected at concentrations near the OSHA PEL. Total chromium was detected in two samples, but not at concentrations that warrant concern.

Silica and Total Particulates

The sample analyzed for silica and Total particulates did not exceed the respective OSHA PELS. No silica was detected in the samples, and the total particulate concentrations were below the current OSHA PEL.

recommendations

Based on trie findings and conclusions presented above, EE&G recommends the following!

Air sample data should continue to ba collected for the duration of the project. This is based on the non-homogeneous nature of the material, as well as the variation in ambient conditions that may have an impact on exposure potentials.

L1 'd OG.'Zl SOOS IS

CITY_21MC100_008110502

NYC-WTC_000289899

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000289899Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000289902

Summary of personal exposure air monitoring data collected for DSNY at the Staten Island landfill on 11/16/01.

Similar indexed content

Compare copies and versions →