If the results of total particulates exceed the corresponding PEL for the
respirable fraction (5 mg/m'’), samples for respirable particulates should
be collected and analyzed-
Employees working at the Hamilton Avenue marine transfer station
should wear persona! protective equipment including half-face negative
pressure respirators equipped with dual cartridge organic vapor and P-
100 filters, and disposable protective clothing. Other hazards in the work
area may necessitate the use of hard hats, hearing protection, eye
protection, and foot protection While the air samples indicated
concentrations significantly below the OSHA PELs, it is the opinion of
EE&G that, the use of personal protective equipment is warranted.
Workers should be informed of the results of the exposure monitoring
described in this report. The attached spreadsheet can be used for this
purpose, or EB&G can provide a different format, if requesfed.