Summary of air sample data, Staten Island project, 1/25–2/1/02

Machine-extracted title · confidence 42%

EE&G summary tables of personal exposure air monitoring data for DSNY Staten Island.

NYC-WTC_000432228–000432230
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Kevin Riehn February 7, 2002 Page 2

CONCLUSIONS

Asbestos

OSHA has an established PEL for asbestos of 0.1 f/cc measured as an 8-hour TWA. and an excursion limit of 1.0 f/cc measured over a 30-minute period. However, several sources have suggested that disease can be caused by exposure to asbestos at concentrations below the OSHA PEL. None of the samples colieded in the time period covered by this report exceeded the OSHA PEL. Although these data indicate that airborne asbestos fiber concentrations are below the OSHA PEL, they do not indicate an “asbestos free* environment, information horn dust samples at the WTC site in Manhattan suggest that over 95% of the asbestos fibers deteded were smaller than_0.25 micron in width, below the detection limit of the NIOSH PCM (7400) and TEM (7402) methods (Granger, et. al. Preliminary Health Hazard Assessment: World Trade Center Brief Communication: Technical Nde. Submitted to American Industrial Hygiene Association, Odober 2, 2001). Approximately 20% of these PCM samples were analyzed by transmission electron microscopy (TEM) for quality control purposes. The results of the TEM analysis will be reported under separate cover.

Metals None of the metals analyzed were detected at concentrations near the OSHA PEL.

Silica and Total Particulates None of the samples collected and analyzed for silica and total particulates exceeded their respective OSHA PELs.

RECOMMENDATIONS

Based on the findings and conclusions presented above, EE&G recommends the following:

Air sample data should continue to be collected for the duration of the project. This is based on the exposure data which suggests that some activities could result in exposures, as well as the non-homogeneous nature of the material being inspected, changing workforce, varying weather conditions, etc.

Employees working in or near the sorting and sifting areas should wear personal protective equipment induding half-face negative pressure respirators equipped with dual cartridge organic vapor and P-100 filters, and disposable protective dothing. Other hazards in the work area necessitate the use of protedive dothing (Tyvek suits), hard hats, hearing protection, eye protection, and foot protedion. Additionally, there may be other chemical substances contained in the debris and ash that are not being tested for frequently; consequently, continued use of the respiratory protedion. as defined in the Health and Safety Plan, is recommended.

05264 CONFIDENTIAL, CITY_2IMCl00_010710775 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000432229

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000432229Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →