Summary of air sample data, DSNY 3/1–3/4/02

Machine-extracted title · confidence 64%

Air sample data collected on 3/1 and 3/4/02 for Staten Island project; EE&G involvement.

NYC-WTC_000245975–000245977
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Kevin Riehn March 11,2002 Page 2

CONCLUSIONS

Asbestos

None of the samples collected in the time period covered by this report exceeded the OSHA PEL. OSHA has an established PEL for asbestos of 0.1 f/cc measured as an 8- hour TWA, and an excursion limit of 1.0 f/cc measured over a 30-minute period. However, several sources have suggested that disease can be caused by exposure to asbestos at concentrations below the OSHA PEL. Although these data indicate that airborne asbestos fiber concentrations are below the OSHA PEL, they do not indicate an “asbestos free” environment. Approximately 20% of these PCM samples were analyzed by transmission electron microscopy (TEM) for quality control purposes. The results of the TEM analysis will be reported under separate cover.

Metals

None of the metals analyzed were detected at concentrations near the OSHA PEL.

Silica and Total Particulates

None of the samples collected and analyzed for silica and total particulates exceeded their respective OSHA PELs.

RECOMMENDATIONS

Based on the findings and conclusions presented above, EE&G recommends the following;

Air sample data should continue to be collected for the duration of the project. This is based on the exposure data that suggests that some activities could result in exposures, as well as the non-homogeneous nature of the material being inspected, changing workforce, varying weather conditions, etc.

Employees working in or near the sorting and sifting areas should wear personal protective equipment including half-face negative pressure respirators equipped with dual cartridge organic vapor and P-100 filters, and disposable protective clothing. Other hazards in the work area necessitate the use of protective clothing (Tyvek suits), hard hats, hearing protection, eye protection, and foot protection. Additionally, there may be other chemical substances contained in the debris and ash that are not being tested for frequently; consequently, continued use of the respiratory protection, as defined in the Health and Safety Plan, is recommended.

Workers should be informed of the results of the exposure monitoring described in this report. The attached spreadsheet can be used for this purpose, or EE&G can provide a different format, if requested.

0311dsny.doc

NYC-WTC_000245976

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000245976Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →