Morbidity weekly report, WTC-related exposures

Machine-extracted title · confidence 30%

CDC MMWR report on occupational exposures post-WTC, May 2002

NYC-WTC_000303073–000303075
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

454 MMWR May 31,2002

BS^ 8 I All samples were collected and analyzed according to the NIOSH Manual of Analytic Methods (5) with some modifi­ cations. A total of 29 bulk samples of undisturbed settled material ^■W»»S*SWW s Al from various locations was analyzed for asbestos; 27 of these also were analyzed for crystalline silica and metals. Of the 29 samples, 26 (90%) had <1% asbestos (by mass); the three Pi others had 1%—3%. All but one of 27 samples had crystalline silica; concentrations (by mass) ranged from 0-18%, with a I median (for all 27 samples) of 3.2%. The most abundant metals in the samples were calcium, magnesium, aluminum, ilsi »-5l iron, and zinc. Lead, arsenic, cadmium, and beryllium con­ centrations (by mass) were <0.1%. Three bulk samples of fire­ - proofing material on I-beams from the main debris pile were analyzed for asbestos; one was negative, and two had <1% asbestos. A sample of paint from a metal beam had 0.3% lead. Phase contrast microscopy (PCM) revealed fibers in 358 (45%) of the 804 asbestos air samples. Excluding 30-minute samples, 25 samples had fiber concentrations that, if the

B fibers had been asbestos, would have exceeded the REL of 0,1 fibers per cubic centimeter of air (f/cc) (7). None of the

SB 30-minute sample concentrations exceeded the OSHA short­ term excursion limit of 1.0 f/cc (2). Of the 25 samples with SBS ific and I fiber concentrationsi:0.1 f/cc (range: 0.1-0.5 f/cc) by PCM, 18 were analyzed by transmission electron microscopy (TEM), ’ a ■ S which can distinguish between asbestos and nonasbestos ; 4' fibers. All had asbestos concentrations <0.1 f/cc. The seven iybl •,4;' ^1' p^< samples not analyzed by TEM had fiber concentrations rang­ t bbl i'l'- ing from 0.1—0.2 f/cc. Differential analysis by polarized light /bbS 'j ,... ■ /fitynda Maibca.Sl4fctl.Vl5% microscopy of these same 25 air samples revealed most nonasbestos fibers to be fibrous glass, gypsum, and cellulose. Air concentrations of total (36 samples) and respirable (18 samples) particulate ranged up to 2.3 milligrams per cubic meter (mg/m^) and 0.3 mg/m^, respectively, which are 4 ’■ 1 below the corresponding RELs of 10.0 mg/m^ and 5.0 mg/m^ ailnforn for Portland cement (7). Respirable crystalline silica was not My detected in any of 18 air samples. Of 45 air samples analyzed S'Erical for various metals, one from a 6'/2-hour PBZ sample from a

fa I

>f'public H s I/” . ’r torch cutter had a cadmium concentration (8.6 microgram per cubic meter [//g/m^]) that would have exceeded the PEL (8-hour time-weighted average [TWA]) of 5.0 /<g/m^ even without further exposure during the remainder of the 8-hour ’ Nolifi- Morbidity^ shift. None of the samples had concentrations of lead, lO ■'■'ill arsenic, beryllium, or other metals that exceeded NIOSH or

SIS0a teii »f>or^ OSHA exposure limits.

III III abs^ H-W ifeteka a 21 -WS Two instantaneous peak CO measurements (1,239 and . 1,368 parts per million [ppm]) exceeded 1,200 ppm, the level 4 NIOSH considers an immediate danger to life and health (7). One was from a torch cutter and the other from a gaso­ Lai ab2i*i siZ , ;ib line-powered saw operator. In 99 air samples, concentrations

CITY_21MC100_009029608 1 NYC-WTC_000303074

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000303074Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →