NYC 9/11 Public Portal Document
ATTACHMENT 2
WTC Indoor Air Monitoring - Sampling and Analytical Procedures
Analytical
Media Sampling Points Sampling Method Proposed Sampling Vulnerability/Practicality Analytical Method Proposed
Parameters
Carpets, fabric furniture or
Settled drapery in areas of activity This is a miCTO vacuuming method. Three collocated samples will
Dust Asbestos ASTM D 5755-95 ASTM D 5755-95
fl lying rooms, family be collected from each location.
Porous rooms)
Sort
surfaces Lead This is a micro vacuuming method. Three collocated samples will
ASTM E 1973-99 SW-846 601OB
be collected from each location.
Horizontal surfaces of
tables or counters and
Asbestos ASTM D 6480-99 Wipe Samples ASTM D 6480-99 (wipe)
bare floors, ceilings and
walls in areas of activity
'living rooms, family
rooms) Lead ASTM El728 Wipe Samples SW-846 601 OB
Settled
Dust
Non-porou Dioxins ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8290
s Hard
surfaces PAHs ASTM D 6661 01 Wipe Samples ASTM 6661-01/SW-846 8270C
Silica ASTM E 1728** Wipe Samples NIOSH 7500 (XRD)
MMVF ASTM D 6480-99 Samples will be combined with the asbestos sampling. EMSL MSD.0300
Arenas of known activity Air pump operated at lOUmin for 8 hours to achieve the COPC PCM NIOSH 7400 followed by TEM AHERA
OMng rooms, family AsbestoSb IIO!
..j dI 3 wkgroup detection limits method.
- —rooma)------------
IIO!
€ "Air pi ited at lOUmin for 8 hours to achieve the COPC
SW-846 601 OB
wkgroup detection limits
TBITPeriWI^Bmpl^BlaffB"
PAHs requirements and to account for Pilot clean-up study only SW-846 8270
break through on the cassettes.
Indoor Air------
TBD Pending sample volume
o Pilot clean-up study only. Availability of sample cassettes for
Dioxins requirements and to account for SW-846 8290
riinxins analysis is questionable Apparently the supply is low.
H break through on the cassettes.
Air pump operated at 2.5Umin for 8 hours to achieve the COPC
Silica NIOSH 7500 NIOSH 7500 (XRD)
wkgroup detection limits
S
O Assumed that it behaves the same as asbestos, samples will be
MMVF NIOSH 7400 EMSL MSD.0300
combined with the asbestos sampling.
O
I
O NOTE; All samples (cassettes and wipes) will be preweighed by the laboratory or supplier prior to sample collection. After sample collection and upon receipt of the samples by the laboratory, the laboratory will weigh
o the sample wipe or cassette prior to performing the analysis. This may change depending upon the availability of preweighed materials. May collect samples for total dust
co
o ** Silica will be collected as a dust samples as is Lead. This was decided since pulverized silica would be particulate like and not fiber like as with asbestos and MMVF.
cn
re
NYC-WTC_000280220
OCR can misread numbers and units. Confirm readings against the page image before using them.