Lab report: PCM fiber results, 98- bv-s71b

Machine-extracted title · confidence 20%

PCM fiber results with sample identifiers and flow details.

NYC-WTC_000278030
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

2 S^.,oJ t: 98-bv-s71b < ( § 1^ Client Name; Applied Technology Services, Inc. o co o Phase Contrast Microscopy (PCM) Fiber Results o o u A98113; Fitterman Hall c 00 CT o Flow Air Fiber Fibers o' co o SciLab Client Date "0 Rate Duration Filtered Fields Fibers Density Cone. TWA o Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm ) (Fibers/cc) 03

O 01 YR-090998-01 9/9/98 4 480 1920 100 72 91.72 0.018 o o By the Tent #1 West Side 14th Fl. c 3 02 YR-090998-02 9/9/98 4 480 1920 100 4 5.10 < 0.001 Q 3 By the Tent #3 Southwest Comer 14th Fl. 03 YR-090998-03 9/9/98 4 480 1920 100 6 7.64 0.002 By the Tent #4 on South Wall 14th Fl. 04 YR-090998-04 9/9/98 4 480 1920 100 22 28.03 0.006 By the Tent #6 Southeast Comer 14th Fl. 05 YR-090998-05 9/9/98 4 480 1920 100 66 84.08 0.017 By the Tent #9 East Wall 14th Fl. 06 YR-090998-06 9/9/98 4 480 1920 100 4 5.10 < 0.001 By the Tent #7 07 YR-090998-07 9/9/98 0 0 0 100 0.5 0.64 Field Blank Footnotes: 7 08 YR-090998-08 9/9/98 0 0 0 100 0.5 0.64 Field Blank Footnotes: 7 Reporting Notes: (1) Fibers/cc cannot be calculated to samples (or blanl^) with np air volume. Analyzed by: Larisa Srybnaya _______ ; Date Analyzed; 9/10/98 Samples analyzed by NIOSH 7400(A) METHOD, Issue #2,'^/! 5/94; Limit of Detection = 5.5 fibers per 100 fields or 7 fibers / mm2; This report relates ONLY to the sample analysis expressed ; as fibers/sq mm of filter area; ND = no fibers observed; NA = Not Analyzed; Walton - Beckett gradicule field area 0.00785 mm2; Duration in minutes; TWA = 8Hr TWA calculation assumes zero exposure for remainder of 8 hour period not sampled; Upper 95% Confidence Limit (Employer’s Compliance Test) - Calculated as a one sided UCL to determine 95% certainty of compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation: Intralab Sr = 0.270. Interlab Sr = 0.450. ELAP #11480 o

1*^ [SJ h-1 s o h-1 o o I o o Co

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000278030Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →