NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.2
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

PCM fiber results lab report, Aug 1997

Machine-extracted title · confidence 95%

Laboratory report documenting PCM fiber analysis results for air samples collected on August 28, 1997.

NYC-WTC_000186282
Page image
Scanned page image, NYC-WTC_000186282
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

(

Client Name: Applied Technology Services, Inc. Phase Contrast Microscopy (PCM) Fiber Results A97195; FH 2nd Fl. DURINGS Flow Air Fiber Fibers iLab Client Date Duration iple # (liUtrimin.) Fillercd Fields Fibers Density Cone. lyvA Sample # / Location (liters) {Fibers/mm ) (Fibers/cc) I 86-082897 01 8/28/97 0 0 0 too 0.5 0.64 Field Blank Footnotca: I 2 86-082897-02 8/28/97 0 0 0 too 0.5 0.64 Field Blank Footnoles! / 3 86-082897-03 8/28/97 5 240 1200 too 36 45.86 0.015 East Side Of Tent IWA -DUR 4 86-082897-04 8/28/97 5 240 1200 too 29 36.94 0.012 West Side Of Tent IWA - DUR 5 86-082897-05 8/28/97 5 240 1200 too 9 11.46 0.004 Al Exhaust of AHJ OWA - DUR 5' 86-082897-06 8/28/97 5 160 800 NA East Side Of Tent IW.A - DUR Foolnatei: 2 7 86-082897-07 8/28/97 5 160 800 NA West Side Of Tent IWA - DUR Foolnolci:' 2 .1 86-082897-08 8/28/97 5 160 800 too 4 5.10 < 0.003 At Exhaust of AFU OWA ■ DUR eporting Notes: (I) Fibers/cc cannot be calculated for sainplet (or blanks) with no air volume. (2) Analyst was unable Io quantify fiber concentration because of :i1oading of particulale material on the filter. Analyzed by: Rlex Zalyaznik f- > Date Analyzed: 8/28/97 BLAP # 11480. Sainplei analyzed by NIOSII 7400(A) METHOD, Issue 82, 8/15/94; Limit of Detection = 5.5 fibers per 100 fields or 7 fibers / mm2; This report lelates ONLY to the sample analysis expressed as fibers/sq ram of filter area; ND = no fibers observed; NA = Not Analyzed; Walton - Beckett gradlcule field area 0.00785 mni2; Duration in minutes; TWzA = Sllr TWA calculation assumes zero exposure for remainder of 8 hour period not sampled; Upper 95% Confidence Limit (Employer's Compliance Test) - Calculated as a one sided UCL to determine 95% ceilaiiity of compliance with the 0.01 fiber/ce standard; Estimated relative standard deviation; Iniralab Sr = 0.270, Intedab Sr = 0.450. Phase Contrast Microscope: Olympus, Model ClI-2. o H

to

S o o o I o

Ui o

NYC-WTC_000186282

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000186282Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →