PCM fiber results lab report, Aug 1997

Machine-extracted title · confidence 95%

Laboratory report documenting PCM fiber analysis results for air samples collected in August 1997.

NYC-WTC_000186280
Page image
Scanned page image, NYC-WTC_000186280
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

< ( I LabJob#: 08-97-6423 lent Name; Applied Technology Services, Inc Phase Contrast Microscopy (PCM) Fiber Results Backgrounds Bate Flow Duration Air Fiber Fibers > Client Density Cone. TWA Filleted Fieius Pibcrg Sample # / Location Collected , (min.) (Fibers/mai * ) (Fibcis/ec) (Iileis/min.) (liters) 29 081997 09 8/19/97 15 80 1200 100 7 8.92 0.003 Bkg-lfl n WtsI Middle of Area ISWA 29 081997 10 8/19/97 15 80 1200 100 4 5 10 < 0.002 Bkg-lsl Pl-West South Corner Area ISWA 29 081997 II 8/19/97 15 80 1200 lOO 5 6.37 < 0.002 Bkg-lsi Fl Noith Baal Comer OSWA 29 081997 12 8/19/97 15 80 1200 1O0 4 5.10 < 0.002 Bkg-lil Fl-Noflh West Comer OSWA 29 081997 13 8/19/97 15 80 1200 100 3 3.82 < 0.002 Bkg- III n Nortfa Wesi Middle of Loading Dock OSWA 29 081997 14 8/19/97 15 80 1200 100 3 3 82 < 0.002 Bkg-lsl n West South Corner OSWA 29 081997 15 8/19/97 15 80 1200 100 7 8.92 0.003 Bkg-lsl H South East Comer OSWA 29 081997 16 8/19/97 0 0 0 100 0 5 0 64 Blank Footnotes: / 29 081997 17 8/19/97 0 0 0 100 0.5 0 64 Blank Footnotes: / lortlng Noles: 1 Fibeis/cc cannot be calculated for samples (nr ^uks) with Analyzed by: Pllex Zalyaznik r ; Dale Analyzed: 8/22/97 RL/kP # 11480. Samplei analyzed by NIOSII 74O(XA) MEHIOD, Blue #2. 8/15/94; Litnl of Deteclion a 5.5 fibers per 100 fields or 7,fibers / min2: This report relates ONLY to the sample analysis expressed as (ibers/sq mm of fillet area; ND = no fibers ohsersed; NA = Not Analyzed; Walton - Bccketl giadicule field area 0 00785 mm2; I Jut alien in iiiinute,s; TWA = Sllr TWA calculation astumei o zero exposure for remainder of 8 hour period not sampled; Upper 95% Confidence Limit (Employer's Compliance I'esl) - Caleulaled as a one sided UCL to ticleimine 95% ceitainiy of H compliance with the 0.01 fiber/cc ilindatd; Estimalcd relative standard deviation: Intralab St = 0.270, Inlerlab Sr = 0.450. Phase Contrast Microscope: Olympus, Model CH‘2, K I to

o s o o I o

o Cn

NYC-WTC_000186280

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000186280Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →