PCM fiber results lab report, Sept 1997

Machine-extracted title · confidence 95%

Laboratory report documenting PCM fiber analysis results for air samples collected on September 22, 1997.

NYC-WTC_000186283
Page image
Scanned page image, NYC-WTC_000186283
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

f t iiciLaO Job .. J9-97 - 615 9 Client Name: Applied Technology SeiYices, Inc, Phase Contrast Microscopy (PCM) Fiber Results A97195; DURINGS p'®'* Duration Air Fiber Fibers L'iLab Client Date Filtered Fielils Fibers Density Colic. TWA ,mp!e # Saiiipic # / Locouon Colicci&d (lilers/min.) '***“•' (Fibers/mm '' ) (Fibers/cc) (liters) 01 29 092297 01 9/22/97 5 430 2150 100 5 6.37 < 0.001 DUR- 1st Fl Clean Room Decon 02 29 092297 02 9/22/97 5 430 2150 100 4 5.10 < 0.001 DUR- 1 st Fl N/E Comer by Tenl OWA 03 29 092297 03 9/22/97 5 430 2150 100 10 12.74 0.002 DUR- Isl El N/Side by Tent OWA 34 29 092297 04 9/22/97 5 430 2150 100 9 I 1.46 0.002 DUR- Isl FI N/West Comer by Tent OWA f)5 29 092297 05 9/22/97 5 430 2150 100 5 6.37 < 0.001 DUR- Isl Fl W/Sideby Tenl OWA 36 29 092297 06 9/22/97 0 0 0 100 0.5 0.64 Blank Fuutiicles: / )7 29 092297 07 9/22/97 0 0 0 100 0.5 0.64 Blank Foolnotes: / Reporting Notes: (1) Rbers/cc cannot be calculated for'MmplesT^)j&ai4s9 wiljr no air volume. Analyzed by; Marvin Brothers ft Oale Artalyzed; Samples analyzed by NIOSH 7400(A) METHOD, Issue W2, 8/15/94; Limit of Detection = 5..5 fibers per 100 fields or 7 fibers / nim2; This report relates ONLY Io the sample analysis expressed as Rbers/sq mm of filler area; ND = no fibers observed; NA = Not Analyzed; Walton - Beckett gradicule field area 0.00785 mm2; Duration io minutes; TWA = 8Hr TWA calculation assumes zero exposure for remainder of 8 hour period not sampled; Upper 95% Confidence Limit (Employer's Compliance Test) - Calculated as a one sided UCL to detenninc 95% certainly of compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation: Intralab Sr = 0,270, Interlab Sr = 0.450.

O

H

to

S o o o I o

o

NYC-WTC_000186283

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000186283Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →