SciL #: 202021828 Pag of 1
Client Name: TRC Environmental Corporation
Phase Contrast Microscopy (PCM) Fiber Results
35052-0000-00007; NYC Law Department; 100 Chruch Street / OSHA
Flow Air Fiber Fibers
SciLab Client Dat® Rate Duration Filtered Density Cone.
Fields Fibers TWA
Sample # Sample # / Location Collected (Hters/min.) (min.) (liters) (Fibers/mm^ ) (Fibers/cc)
01 GS-2/8/02-STEL-0501 2/8/02 2 30 60 NA
Marion Hendy Footnotes: 2
02 GS-2/8/02-STEL-0502 2/8/02 2 60 120 100 3 3.82 <0.022
Mike Luna
03 GS-2/8/02-STEL-0503 2/8/02 0 0 0 100 0.5 0.64
Blank Footnotes: 7
04 GS-2/8/02-STEL-0504 2/8/02 0 0 0 100 0.5 0.64
Blank Footnotes: 7
Reporting Notes:
(1) Fibers/cc cannot be calculate^ondamples (or blanks) with no air volume.
(2) Analyst was unable^ lUi fntri ttoft-because of overloading of particulate material on the filter.
Analyzed by: Tatyana Grimchak.—:; 1____ ; Date Analyzed: 2«/02
Samples analyzed by NIOSH 7400(. '1; Limit of Detections 5.5 fibers per 100 fields or 7 fibers/mm2; This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area; ND=No fibers observed: NA= Not
Analyzed; Walton-Beckett graticle f Id are! mm2: TWA = 8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled; Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to
determine 95% certainty of compliance with the 0.01 fiber/cc standard: Estimated relative standard deviation: Intralab Sr=0.405. Interlab Sr=0.45, New York samples (NYSDOH ELAP Lab # 11480); National Institute of Standards and Technology