z ( ( Z o o 6ci! Job#: 98-08-68G5 co § Client Name: Applied Technology Services, Inc. o U o Pha.se Contrast Microscopy (PCM) Fiber Results c o CT 00 A98113; 7th & Sth Floor-Finals o' 03 KJ U O CO Flow Air Fiber Fibers 3. O 03 SciLab Client D®*® Rate Duration Filtered Density Cone. Fields Fibers TWA Sample # Sample # i Location Cuiiecied (liters/min.) (min.) (liters) (Fibers/mm ) (Fibers/ee) o o o c 01 34082098-01 8/20/98 0 0 0 100 0.5 0.64 3 Footnotes: ; CD Field Blank 02 34082098-02 8/20/98 0 0 0 100 0.5 0.64 Field Blank Footnotes: /

03 inside 34082098-03 8/20/98 15 80 1200 100 4 5.10 < 0.002 7tb Flr.-Tent #59 04 outside 34082098^04 8/20/98 15 80 1200 100 5 6.37 < 0.002 7th Flr.-Tent #59 05 inside 34082098-05 8/20/98 15 80 1200 100 13 16.56 0.005 Sth Fk.-Tfcnt#60 06 outside 34082098-06 8/20/98 15 80 1200 100 4 5.10 < 0.002 8th Flr.-Tent #60 07 inside 34082098-07 8/20/98 15 80 1200 100 7 8.92 0.003 8tb Flr.-Tent #61 08 outside 34082098-08 8/20/98 15 80 1200 100 5 6.37 < 0.002 8th Flr.-Tent #61 09 inside 34082098-09 8/20/98 IS 80 1200 100 7 8.92 0.003 Sth Flr.-Tent #62 10 outside 34082098-10 8/20/98 15 80 1200 100 4 5.10 < 0.002 Sth Flr.-Tent #62 Reporting Notes: (1) Fibers/cc cannot be calculat^d^ san^ey^Kblanks) with no air volume. Analyzed by: Marvin Brothers jl \ V—------ —"_________ ; Date Analyzed: 8/20/98 o Samples analyzed by NIOSH 7400(A)ME™OD71ssiie#278n5/94rLimit of Detection = 5.5 fibers per 100 fields or 7 fibers / mm2; This report relates ONLY to the sample analysis expressed H K as fibers/sq mm of filter area; ND = no fibers observed; NA = Not Analyzed; Walton - Beckett gradicule field area 0.00785 mm2; Duration in minutes; TWA = 8Hr TWA calculation assumes I zero exposure for remainder of 8 hour period not sampled; Upper 95% Confidence Limit (Employer’s Compliance Test) - Calculated as a one sided UCL to determine 95% certainty of to

S compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation: Intralab Sr = 0.270, Interlab Sr = 0.450. ELAP #11480 O o o 1^ o co

o o co

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000186290Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →