0.01 f/cc. The TEM AHERA results indicate that two of the samples were below the
detection limit and the third was at the detection limit with all three being below the
secondary numeric criterion of 0.022 S/cc. The TEM PCMe results indicate that two
of the samples were below the detection limit and the third was at the detection limit
with all three being below the primary numeric criterion of 0.0009 S/cc.
Gypsum
Before Cleaning Samples - There was one pre-cleaning wipe sample collected from
the HVAC system. The results indicate gypsum was not detected above the detection
limit lOmg/m^.
Post Cleaning Samples, HVAC System - There was one air sample and two wipe
samples collected after the first cleaning. The results indicate that gypsum was not
detected above the detection limit of 0.008 mg/nf for the air samples, and not
detected above the detection limit of 10 mg/m^ for wipe samples.
Lead
Before Cleaning Samples - There were one pre-cleaning wipe sample collected from
the HVAC system. The results indicate lead was detected above the primary numeric
criterion of 25 pg/lV at 1310 pg/ft^
Post P' Cleaning Samples, HVAC System - There were two air samples, and two wipe
samples collected after the first cleaning. The two air samples were below the
detection level and primary numeric criterion of 1 pg/m\ The results of the two wipe
samples show that lead concentrations exceeded the numeric criterion at 136 pg/iV
and 183 pg/f?. The post-cleaning lead exceedances were attributed to the
composition of the HVAC construction material.
Post P' Cleaning Samples, Test 4A - There were five post cleanup air samples
collected, all of which were below the detection level.
Alpha Quartz
Before Cleaning Samples - There was one pre-cleaning wipe sample collected. The
sample had alpha-quartz detected at a concentration of 313 mg/m\
Post Cleaning Samples, HVAC System - There were two wipe samples and one air
sample collected after the first cleaning. The air sample was below the detection
limit. Both wipe samples were above the detection limit. During the validation
process, one wipe sample was qualified due to the duplicate being out of the control
range.