INTERNAL REVIEW DRAFT

sample which was analyzed indicates that dust was present at concentrations lower than the pre-cleaning and Test 4A concentrations.

Elevator Shaft/Compactor Room - This area consisted of a soil floor in an elevator shaft and a concrete floor in an adjacent compactor room. Construction was of cinder block walls and exposed floor joists.

Cleaning method - This area was cleaned using test method 4A. Test method 4A used an industrial HEPA filtered vacuum and an air filtration device (AFD). No wet wiping was performed.

Numeric Criteria - This unit met the numeric criteria listed in Table 1 for each compound after being cleaned once.

Asbestos Before Cleaning Samples - There were no before cleaning samples collected.

Post Cleaning Samples - There were three post-cleaning air samples collected. The three air samples were analyzed using PCM, TEM AHERA, and TEM PCMe. The three PCM results were all below the secondary numeric criterion of 0.01 f/cc. Two of the three were below the detection limit. Similarly, the TEM AHERA results were all below the secondary numeric criterion of 0.022 S/cc. All three of these samples were also below the detection limit. The TEM PCMe results were all below the primary numeric criteria of 0.0009 S/cc with all three of the samples being below the detection limit.

Lead Before Cleaning Samples - There were no before cleaning samples collected.

Post P' Cleaning Samples - There were two air samples collected after the first cleaning. The two air samples were below the detection limit.

MMVF Before Cleaning Samples - There were no before cleaning samples collected.

Post P' Cleaning Samples - There were three air samples collected after the first cleaning. The results indicate that MMVF was present in each of the three samples; however, the concentrations were below the numeric criterion of 10 S/L.

Commercial Unit: The Food Exchange Restaurant - This is a 5,000 sq. ft. restaurant occupying three floors. The first floor is at street level with entrances from both Liberty and Cedar Streets. This floor was used for food service and customer dining. The lower level

95

CITY_21MC100_0 04205051

NYC-WTC_000276747

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276747Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →