Post J"' Cleaning Samples, Test 4C - There were five air samples collected after the
first cleaning. All of the air samples indicate that MMVF was present but at levels
below the numeric criterion of 10 S/L.
Post J" Cleaning Samples, Test 4D - There were three air samples collected after
cleaning. All of the air samples indicate that MMVF was present but at levels below
the numeric criterion of 10 S/L.
PAHs
Before Cleaning Samples - There were two pre-cleaning air samples and four pre
cleaning wipe samples collected. The two air samples both detected six PAH
compounds; however, the calculated TEFs were below the primary numeric criterion
of 0.2 pg/m^. Two of the four wipe samples also detected three PAH compounds;
however, the calculated TEFs were below the primary numeric criterion on 300
pg/m^. The remaining two samples were below the detection limit and the TEF for
each sample was below the numeric criterion.
Post P' Cleaning Samples, Test 4A - There were four post-cleaning wipe samples
collected. All four samples were below the detection limit and the TEF for each
sample was below the numeric criterion of 300 pg/m^.
Post P' Cleaning Samples, Test 4B - There were four post-cleaning wipe samples
collected. All four samples were below the detection limit and the TEF for each
sample was below the numeric criterion of 300 pg/nV.
Post P' Cleaning Samples, Test 4E - There were three post-cleaning wipe samples
collected. All three samples were below the detection limit and the TEF for each
sample was below the numeric criterion of 300 pg- nr.
Total Dust
Before Cleaning Samples - There were four pre-cleaning wipe samples collected;
however, EPA only requested to have two of the samples analyzed. The results
indicate that dust was present.
Post P' Cleaning Samples, Test 4A - There were four post-cleaning wipe samples
collected; however, EPA only requested to have one of the samples analyzed. The
sample which was analyzed indicates that dust was present at concentrations lower
than the pre-cleaning concentrations.
Post P' Cleaning Samples, Test 4B - There were four post-cleaning wipe samples
collected; however, EPA only requested to have one of the samples analyzed. The
94