4. HEPA-filtered upright and shop vacuums with the addition of an AFD
5. Industrial quality HEPA-filtered vacuums
6. Industrial quality HEPA-filtered vacuums with the addition of an AFD
7. Wet wiping of all horizontal and/or vertical surfaces with soap and water
8. Carpet cleaning
9. Standard cleaning procedures used by professional duct cleaning companies for the
cleaning of air conditioning (A/C) systems, ducts and related equipment
10. Use of water only for wet wipe of horizontal and/or vertical surfaces
11. Scope A cleaning procedures developed by EPA and New York City for the cleaning of
of units in lower Manhattan
Determination of which cleaning method would be studied in each rental unit was based on the
apparent level of impact that unit had endured as a result of the WTC collapse. EPA developed a
set of four tests to facilitate assignment of cleaning methods to the rental units. The tests
described levels of readily observable impact by WTC dust, and prescribed six of the eleven
cleaning methods to be used to respond to each level of impact. Up to five different cleaning tests
were tested in each residential and commercial units. Factors related to level of impact included
directional exposure to Ground Zero and location of the unit in the building.
At project commencement, a visual assessment of the level of impact each rental unit had
endured was performed which was in turn utilized to correlate each rental unit to an applicable
cleaning test. The assignment process was modified to ensure that each of the cleaning methods
was applied to units that had experienced both low and high levels of observable impact.
The effectiveness of the various Study cleaning methods were evaluated through the collection
and analysis of pre-cleanup and post-cleanup samples, and comparison of the resulting analytical
data to Chemicals of Potential Concern to determine if the cleaning method achieved health
based screening levels. The COPCs used in this study were: asbestos air by PCMe, lead air and
settled dust, dioxin air and settled dust, PAHs air and settled dust, fibrous glass (MMVF) air, and
crystalline silica (alpha quartz) air. Sample collection methods were identified to achieve the
health-based levels.
Data was also evaluated from other compounds that do not have health-based benchmarks, and
data on COPC compound which did not have established health-based benchmarks. These
included asbestos in air by PCM and TEM AHERA, asbestos settled dust, calcite air and settled
dust, gypsum air and settled dust, cristobolite air and settled dust, tridymite air and settled dust,
fibrous glass (MMVF) settled dust by wipe sampling, silca settled dust by wipe sampling and
total settled dust.
After the initial cleaning of each unit, the OSC reviewed the established cleanup criteria,
reviewed the analytical results, and provided direction as to which units required additional
cleaning. In the event that it was determined that a unit did not achieve the clearance criteria, it
7
CITY_21MC100_004204964
NYC-WTC_000276660