EPA applied up to two cleaning methods in each of thirteen residential units, and up to five
cleaning methods in each of two commercial units. The eleven cleaning methods tested are
presented below;
1. Residential quality upright vacuums and shop vacuums.
2. Residential quality upright vacuums and shop vacuums with the addition of an Air
Filtration Device (AFD).
3. HEPA-filtered upright and shop vacuums.
4. HEPA-filtered upright and shop vacuums with the addition of an AFD.
5. Industrial quality HEPA-filtered vacuums.
6. Industrial quality HEPA-filtered vacuums with the addition of an AFD.
(This cleaning method was used in both residential and commercial units.)
7. Wet wiping of all horizontal and/or vertical surfaces with soap and water.
8. Carpet cleaning.
9. Standard cleaning procedures used by professional duct cleaning companies for the
cleaning of air conditioning (A/C) systems, ducts and related equipment.
10. Use of water only for wet wipe of horizontal and/or vertical surfaces.
11. Scope A cleaning procedures developed by EPA and New York City for the cleaning of
units in lower Manhattan.
Determination of which cleaning method would be studied in each rental unit was based on the
apparent level of impact that unit had endured as a result of the WTC collapse. EPA developed a
set of four tests to evaluate cleaning methods in the rental units. The tests were assigned based
upon readily observable impact by WTC dust, and prescribed six of the eleven cleaning methods
to be used to respond to each level of impact. Up to five different cleaning tests were tested in
each residential and commercial unit. Factors related to level of impact included directional
exposure to ground zero and location of the unit in the building.
At project commencement, a visual assessment of the level of impact each rental unit had
sustained was performed. This assessment was utilized to assign each rental unit to an applicable
cleaning test. The assignment process was modified to ensure that each of the cleaning methods
was applied (tested) in units that had experienced both low and high levels of observable impact.
The effectiveness of the cleaning methods was evaluated through the collection and analysis of
pre-cleanup and post-cleanup samples, and through comparison of the resulting analytical data to
the COPC, to determine if the cleaning method achieved health-based screening levels. The COPC
evaluated in this study were: asbestos in air by PCMe, lead in air and settled dust, dioxin in air
and settled dust, PAH in air and settled dust, fibrous glass (MMVF) in air, and alpha-quartz in air.
Data was also evaluated from other compounds that do not have health-based benchmarks
established in EPA’s COPCZBenchmark Report. These included asbestos in air by PCM and
TEM AHERA, asbestos in settled dust, calcite in air and settled dust, gypsum in air and settled
dust, cristobalite in air and settled dust, tridymite in air and settled dust, fibrous glass (MMVF) in
settled dust by wipe sampling, alpha-quartz in settled dust by wipe sampling and total settled dust.
After the initial cleaning of each unit, the OSC reviewed the established cleanup criteria, reviewed
the analytical results, and provided direction as to which units required additional cleaning. In the
event that it was determined that a unit did not achieve the primary clearance criteria, it was