19 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000232639
Label derived from the City's folder field. The City does not supply document titles.NYC-WTC_000232639–000232659
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Final Report 125 Cedar Street, NYC, NY
Executive Summary
ATC Associates Inc. (ATC) provided project monitoring, air sampling and management serxhces for the interior dust clean-up activities for the unoccupied building located at 125 Cedar Street, New York, New York. Actual field operations were held from September 12, 2002, with the collection of background wipe samples through November 1, 2002 with the completion of post testing. Background wipe samples for settled dust were analyzed in accordance with the project specifications and the individual analytes were as follows: Lead, Mercury, Poly Aromatic Hydrocarbons, and Dioxin. Clean-up activities within the unoccupied building was conducted in accordance with generally accepted industry practices, as well as the Project specification issued by the New York City Department of Environmental Protection
Action Environmental Remediation, Inc., a New York State Department of Labor (NYSDOL) licensed asbestos abatement contractor, performed the cleaning services. ATC performed project monitoring, air sampling and management services for the interior dust clean-up activities including; review of contractor worker certification. Contractor oversight, daily collection and analysis of ambient and clearance air sampling.
Prior to the start of cleaning activities, ATC inspected that each area was under negative air flow to ensure compliance with the project Scope of Work Procedures. Negative air flow entailed the installation of negative air units within the apartments commercial spaces and basement. As the clean-up project progressed, ATC continuously monitored the Contractor’s work practices, generated daily site logs, and collected ambient air samples in areas surrounding the abatement work areas. All ambient air samples collected during this project were less than 70 structures per cubic centimeter as specified, well below acceptable levels established by federal regulations (AHERA).
Once the Contractor completed cleaning activities from within all areas, in accordance with project Scope of Work Procedures, ATC, NYCDEP and USEPA visually inspected each work area to ensure the areas were decontaminated to a level of no visible debris. Pollowing this successful final visual inspection, ATC performed final air and wipe clearance sampling in accordance with project Scope of Work Procedures. Air clearance sampling entailed collection of fiberglass air samples, analyzed via NIOSH method 7400 “B” counting rules, crystalline silica, analyzed via NIOSH 7500, as well as an EPA modified Transmission Electron Microscopy (TEM) AHERA standard referred to as PCMe. All TEM air samples were analyzed by ATC’s New York City laboratory, with all sample results satisfying the accepted final air clearance criteria of less than or equal to 0.0009 f/cc PCMe.
Clearance wipe sampling was performed consistent with generally accepted industrial hygiene practices. There were inherent limitations created by operational and work practice variability, variations in contaminant concentrations, and sampling and analytical accuracy. The acceptable results of the sampling represent conditions found on the dates the samples
ATC Project No. 15.22906.0002 Page 2
CITY_21MC100_009480307
NYC-WTC_000232643
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
No available related records indexed in this group.
Filed elsewhere
19 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗19 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107585
Laboratory data table listing analytical results for various dioxin and dibenzofuran compounds with detection limits.
19 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000129376
Volume 1 of the final documentation report for the WTC unoccupied building monitoring program at 125 Cedar Street.
20 shared non-person entities · 1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176247
Comprehensive environmental assessment report prepared by TRC Engineers for the New York City Law Department.
13 shared non-person entities · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120940
Document tracking environmental samples collected from Building #100 at 345 South End Avenue on October 22, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120991
Record documenting the transfer and custody of air samples from Building #100 at 345 South End Avenue collected on October 22, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000119908
Record documenting the transfer and custody of air samples from 365 South End Avenue collected on October 17, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000108678
Document page summarizing positive and negative counts for asbestos analysis via PLM, PCM, and TEM methods.
8 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121462
Record documenting the transfer and custody of air samples from Building #500 at 385 South End Avenue collected on October 22, 2001.
8 shared non-person entities · 1 shared topics · similarity 0.961
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000129376
Volume 1 of the final documentation report for the WTC unoccupied building monitoring program at 125 Cedar Street.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107585
Laboratory data table listing analytical results for various dioxin and dibenzofuran compounds with detection limits.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.988 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.988 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Similarity score 0.987 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000107585
Laboratory data table listing analytical results for various dioxin and dibenzofuran compounds with detection limits.
Similarity score 0.972 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Buildings in this record
Machine-extracted building matches; verify each source. Buildings, never households.
- 125 Cedar Street · 9 pages · confidence 0.85 · verify page 5
Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Similar indexed content
Similar indexed content
Similar indexed content
NYC-WTC_000107585
Laboratory data table listing analytical results for various dioxin and dibenzofuran compounds with detection limits.
Similar indexed content
Volume 1 of the final documentation report for the WTC unoccupied building monitoring program at 125 Cedar Street.
Similar indexed content