Final Report 125 Cedar Street, NYC, NY

ExEcuTlvE SUMMARY

ATC Associates Inc. (ATC) provided project monitoring, air sampling and management services for the interior dust clean-up activities for the unoccupied building located at 125 Cedar Street, New York, New York. Actual field operations were held from September 12, 2002, with the collection of background wipe samples through November 1, 2002 with the completion of post testing. Background wipe samples for settled dust were analyzed in accordance with the project specifications and the individual analytes were as follows: Lead, Mercury, Poly Aromatic Hydrocarbons, and Dioxin. Clean-up activities within the unoccupied building was conducted in accordance with generally accepted industry practices, as well as the Project specification issued by the New York City Department of Environmental Protection

Action Environmental, a New York State Department of Labor (NYSDOL) licensed asbestos abatement contractor, performed the cleaning services. ATC performed project monitoring, air sampling and management services for the interior dust clean-up activities including; review of contractor worker certification, Contractor oversight, daily collection and analysis of ambient and clearance air sampling.

Prior to the start of cleaning activities, ATC inspected that each area was under negative air flow to ensure compliance with the project Scope of Work Procedures. Negative air flow entailed the installation of negative air units within the apartments, however, beesds+v--typica-cIe st}vi ies t ~elea tag a s eot be sealed; 1 c, _.negativ=. $ ' ,. iwable ered. As the clean-up project progressed, ATC continuously monitored the Contractor's work practices, generated daily site logs, and collected ambient air samples in areas surrounding the abatement work areas. All ambient air samples collected during this I S project were less than 70 structures per cubic centimeter as specified, well below' + rv-c , acceptable levels established by federal regulations (AHERA).

Once the Contractor completed cleaning activities from within Jl areas, in accordance with project Scope of Work Procedures, ATC, NYCDEP and A visually inspected each work area to ensure the areas were decontaminated to a level of no visible debris. Following this successful final visual inspection, ATC performed final air and wipe clearance sampling in accordance with project Scope of Work Procedures. Air clearance sampling entailed collection of fiberglass air samples, analyzed via 1IOSH method 7400 "B" counting rules, crystalline silica, analyzed via NIOSH 7500 as well as an EPA f 5 b modified Transmission Electron Microscopy (TEM) AHERA staltlard referred to as S~ %i cc PCMe All TEM air samples were analyzed by ATC's New York City laboratory, with all san1le results satisfying the accepted final air clearance criteria of less than or equal to 0.0009 f/cc PCMe.

Clearance wipe sampling was performed consistent with generally accepted industrial hygiene practices. There were inherent limitations created by operational and work practice variability, variations in contaminant concentrations, and sampling and analytical accuracy.

ATC Project No. 15.22906.0002 Page 2

NYC-WTC 000107590

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000107590Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000120991 · Box DEP Box 48

Record documenting the transfer and custody of air samples from Building #100 at 345 South End Avenue collected on October 22, 2001.

Similar indexed content

Compare copies and versions →