INTERNAL REVIEW DRAFT
PAHs
Before Cleaning Samples - There were three pre-cleaning wipe samples collected. Two of
the three samples were below the detection limit and the TEF for these samples were below
the numeric criterion. The third sample had four PAH compounds detected and the
calculated TEF was 303.5, which is slightly above the numeric criterion of 300 pg/m^.
Post P' Cleaning Samples - There were four wipe samples collected after the first cleaning.
All of the samples were below the detection limit and the TEF for each sample was below the
numeric criterion of 300 pg/m2 Since all of the samples were below the detection limit and
the numeric criterion after the first cleaning, no additional samples were collected for PAHs.
Total Dust
Before Cleaning Samples - There were three pre-cleaning wipe samples collected; however,
EPA only requested to have one of the samples analyzed. The results indicate that there was
dust present.
Post Cleaning Samples - There were four wipe samples collected after the first cleaning;
however, EPA only requested to have two of the samples analyzed. Both samples indicate
that dust was present; however, the concentrations reported were lower than the pre-cleaning
concentration. This indicates that the cleaning technique used was able to remove dust. As
total dust does not have a numeric criterion and the results indicate that the concentration of
dust was reduced, no additional samples were collected for total dust.
Unit 5D - This is a 1,024 sq. ft. open loft facing the World Trade Center site. This unit had windows
that were blown-in, which resulted in significant dust accumulation. The dwelling had hardwood
floors with no carpet and all personal items were removed prior to cleaning.
Cleaning Method - This unit was cleaned using test method 3B which used an industrial
HEPA filtered vacuum and an air filtration device (AFD). All horizontal surfaces were wet
wiped.
Numeric Criteria - This unit met the numeric criteria listed in Table 1 for each compound
after being cleaned one time.
Asbestos
Before cleaning samples - Pre-cleaning micro vacuum and wipe samples were collected for
asbestos. These samples indicate that asbestos was present in the unit prior to cleaning. The
two micro vacuum samples detected chrysotile above the detection limit. Three of the five
wipe samples were below the detection limit, although four of the five wipe samples detected
either chrysotile or amosite.
79
CITY_21MC1OO_OO42O5O35
NYC-WTC_000276731
OCR can misread numbers and units. Confirm readings against the page image before using them.