Post P‘ Cleaning Samples - Post-cleaning micro vacuum, wipe and air samples were
collected for asbestos. The samples were analyzed for PCM and TEM PCMe. The PCM
results indicate all three samples were below the secondary numeric criterion of 0.01 f/cc.
The PCMe results indicate that all three of the samples were below the primary numeric
criterion of 0.0009 S/cc.
The results of the two micro vacuum samples indicate that asbestos was present at levels
somewhat similar to those observed before cleaning.
The results of the five wipe samples indicate that asbestos was below the
concentrations observed in the pre-cleaning samples and below the detection limit for
all samples.
Dioxin
Before Cleaning Samples - There were four pre-cleaning wipe samples collected and
analyzed for dioxin. The results indicate that there was dioxin present and that the
TEQ concentration for all samples was below the numeric criterion of 4 ng/m^.
Post P' Cleaning Samples - There were four post-cleaning wipe samples collected
and analyzed for dioxin. The results indicate that there was dioxin present; however,
the TEQ concentrations were below the numeric criterion of 4ng/ni‘ and similar to
pre-cleanup concentrations.
Gypsum
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. The
results indicate gypsum was not detected above the detection limit 80 mg/m^.
Post Cleaning Samples - There were two air samples and four wipe samples
collected after the first cleaning. The results indicate that gypsum was not detected
above the detection limit of 0.016 mg/ra’ for the air samples, and not detected above
the detection limit of 80 mg/m^ for wipe samples.
Lead
Before Cleaning Samples - There were two micro vacuum samples and four wipe
samples collected. The results indicate lead was detected in both micro vacuum
samples and two of the four wipe samples at concentrations above the comparison
value or primary numeric criteria of 25 pg/ft^. The micro vacuum samples exceeded
the comparison value, ranging from 27.1 pgZtf to 49.1 pg/ft^ and the two wipe
sample exceeded the primary numeric criteria, ranging from 25.3 pg/ft^ and 32.1
pg/fV.