NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 121 pages

COPCS report, NYC WTC chain of custody

Machine-extracted title · confidence 50%

Table of contents for contaminants of [name] report and building sections.

NYC-WTC_000276652–000276772
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

INTERNAL REVIEW DRAFT

Post P‘ Cleaning Samples - Post-cleaning micro vacuum, wipe and air samples were collected for asbestos. The samples were analyzed for PCM and TEM PCMe. The PCM results indicate all three samples were below the secondary numeric criterion of 0.01 f/cc. The PCMe results indicate that all three of the samples were below the primary numeric criterion of 0.0009 S/cc.

The results of the two micro vacuum samples indicate that asbestos was present at levels somewhat similar to those observed before cleaning.

The results of the five wipe samples indicate that asbestos was below the concentrations observed in the pre-cleaning samples and below the detection limit for all samples.

Dioxin Before Cleaning Samples - There were four pre-cleaning wipe samples collected and analyzed for dioxin. The results indicate that there was dioxin present and that the TEQ concentration for all samples was below the numeric criterion of 4 ng/m^.

Post P' Cleaning Samples - There were four post-cleaning wipe samples collected and analyzed for dioxin. The results indicate that there was dioxin present; however, the TEQ concentrations were below the numeric criterion of 4ng/ni‘ and similar to pre-cleanup concentrations.

Gypsum Before Cleaning Samples - There were four pre-cleaning wipe samples collected. The results indicate gypsum was not detected above the detection limit 80 mg/m^.

Post Cleaning Samples - There were two air samples and four wipe samples collected after the first cleaning. The results indicate that gypsum was not detected above the detection limit of 0.016 mg/ra’ for the air samples, and not detected above the detection limit of 80 mg/m^ for wipe samples.

Lead Before Cleaning Samples - There were two micro vacuum samples and four wipe samples collected. The results indicate lead was detected in both micro vacuum samples and two of the four wipe samples at concentrations above the comparison value or primary numeric criteria of 25 pg/ft^. The micro vacuum samples exceeded the comparison value, ranging from 27.1 pgZtf to 49.1 pg/ft^ and the two wipe sample exceeded the primary numeric criteria, ranging from 25.3 pg/ft^ and 32.1 pg/fV.

80

CITY_21MC100_004205036

NYC-WTC_000276732

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276732Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →