Post P‘ Cleaning Samples - There were two air samples, three micro vacuum samples and
four wipe samples collected after the first cleaning. The two air samples were below the
primary numeric criterion of 1 pg/m\ However, at the time that the results were received, the
numeric criterion that was being used for comparison was the background numeric criterion
of 0.1 pg/m^and not the health-based numeric criterion of 1 pg/m\ which was developed
during the execution of this project. Thus additional air samples were collected after the
second cleaning.
All three micro vacuum samples were below the detection limit. This indicates that the
cleaning techniques used were able to reduce the elevated pre-cleaning lead concentrations
that were observed in the settled dust in the areas where the samples were collected.
The results of three of the four wipe samples were below the primary numeric criterion (one
sample was broken and not analyzed). The results from the first cleaning indicate that the
cleaning technique was effective in removing the elevated concentrations of lead that were
observed prior to the first cleaning. Since the numeric criterion was met for lead after the
first cleaning, no additional lead samples were collected, with the exception of the lead air
samples discussed above.
Post 2"‘' Cleaning - There were two lead air samples collected after the second cleaning. The
results for both of the samples indicate that the samples were below the primary numeric
criterion of 1 pg/m\ Since the numeric criterion was met for lead after the first cleaning, no
additional lead samples were collected.
Alpha-Quartz
Before Cleaning Samples - There were three pre-cleaning wipe samples collected. All three
samples were above the detection limit.
Post P' Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit. Since all of the
samples were below the detection limits after the first cleaning, no additional samples were
collected for alpha-quartz.
Calcite
Before Cleaning Samples - There were three pre-cleaning wipe samples collected. Two of
the three samples were below the detection limit and the third sample was above the
detection limit.
Post P' Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit. Since all of the