NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 171 pages

Citywide EPA WTC report, May 2003

Machine-extracted title · confidence 18%

EPA NYC Region 2 WTC response document, City data file.

NYC-WTC_000431857–000432027
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Post P* Cleaning Samples (Test 3B) - Two air samples, two micro vacuum samples, and four wipe samples were collected after the first cleaning. The two air samples were below the primary clearance criterion of 1.0 pg/m\ The results of the micro vacuum and wipe samples show that all samples met the comparison value or primary clearance criterion for lead.

Alpha-Quartz Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post P‘ Cleaning Samples - Two air samples were collected after the first cleaning. Both were below the detection limit.

Calcite Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post P* Cleaning Samples - Two air samples were collected after the first cleaning. Both were below the detection limit.

Cristobalite Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post P‘ Cleaning Samples - Two air samples were collected after the first cleaning. Both were below the detection limit.

Tridymite Before Cleaning Samples - Pre-cleaning air samples were not collected.

Post P* Cleaning Samples - Two air samples were collected after the first cleaning. Both were below the detection limit.

MMVF Before Cleaning Samples - Four wipe samples were collected. The four wipe samples evidenced MMVF above the detection limit, which indicates that MMVF was present prior to cleaning.

Post P* Cleaning Samples - Three air samples and five wipe samples were collected after the first cleaning. All of the air sample results indicate that MMVF was present, but at levels below the primary clearance criterion of 10 S/L. All of the wipe sample results were in the range of 114.46 S ent to 228.93 S cm". This indicates that the cleaning method was able to reduce the pre-cleaning concentration of MMVF.

PAH Before Cleaning Samples - Four wipe samples were collected. All four samples were below the detection limit, and the TEF of 300 jig m".

Post P* Cleaning Samples - Four wipe samples were collected. All four samples were below the detection limit; the TEF value was below the primary clearance criterion of

78

CITY_21MC100_0 11132957

NYC-WTC_000431938

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000431938Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →