with particulate material. Due to not having valid TEM PCMe results, a third cleaning was
conducted.
Post 3"* Cleaning - There were four asbestos air samples collected after the third cleaning.
The samples were analyzed for PCM, TEM AHERA, and TEM PCMe. The PCM results
indicate that one sample was below the detection limit and the other three were at the
detection limit. All PCM results were below the secondary numeric criterion of 0.01 f/cc.
The TEM AHERA results had chrysotile detected above the detection limit; however, all
four results were below the secondary numeric criterion of 0.022 S/cc. The TEM PCMe
results indicate that the two of the samples which were collected under a modified-aggressive
sampling methodology, were below or at the detection limit. The remaining two samples,
which were collected under an aggressive sampling methodology, were slightly above the
primary numeric criterion of 0.0009 S/cc with results of 0.0015 S/cc and 0.0016 S/cc. The
results obtained from the samples collected with the modified-aggressive sampling were used
as evidence of meeting the primary numeric criterion.
Dioxin
Before Cleaning Samples - There were three pre-cleaning wipe samples collected and
analyzed for dioxin. The results indicate that there was dioxin present; however the TEQ
concentrations for each sample were below the primary numeric criterion of 4 ng/m\
Post P' Cleaning Samples - There were four post-cleaning wipe samples collected and
analyzed for dioxin. The results indicate that the TEQ concentrations for each sample were
below the primary numeric criterion of 4 ng/mf Since dioxin was below the detection for all
of the samples collected, there were no additional dioxin samples collected.
Gypsum
Before Cleaning Samples - There were three pre-cleaning wipe samples collected. The
results indicate that gypsum was not detected.
Post Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. The results indicate that gypsum was not detected in any sample.
Since gypsum was below the detection limit for all of the samples collected, there were no
additional gypsum samples collected.
Lead
Before Cleaning Samples - There were three micro vacuum samples and three wipe samples
collected. The results indicate that lead was detected all three micro vacuum samples at
concentrations above (approximately four to six times) the comparison value of 25 pg/ft^.
Two of the three wipe samples had detectable concentrations of lead above the primary
numeric criterion of 25 pg/ft^, while the third sample was below the primary numeric
criterion.