samples at concentrations below the comparison value of 25 pg/ff. All three wipe samples
had detectable concentrations of lead, two of which were above the primary numeric criterion
of 25 pg/ft^.
Post P' Cleaning Samples - There were two air samples, seven micro vacuum samples and
four wipe samples collected after the first cleaning. The two air samples were below the
primary numeric criterion of 1 pg/m\ All seven micro vacuum samples were below the
comparison value. Two of the four wipe samples exceeded the primary numeric criterion,
thereby making additional cleaning necessary.
Post 2ncl Cleaning Sampling - The sampling results following the second cleaning indicate
that the numeric criterion was met. Three wipe samples were collected following the second
cleaning. The results of all three samples were below the primary numeric criterion. In two
of the samples, lead was not detected.
Alpha-Quartz
Before Cleaning Samples - There were three pre-cleaning wipe samples collected. Alpha
quartz was detected in all three samples.
Post Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit. This indicates the
cleaning techniques were effective at reducing the pre-cleaning concentrations of silica.
Calcite
Before Cleaning Samples - There were three pre-cleaning wipe samples collected. All three
samples were below the detection limit.
Post P' Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit. Since all of the
samples were below the detection limits after the first cleaning, no additional samples were
collected for calcite.
Cristobalite
Before Cleaning Samples - There were three pre-cleaning wipe samples collected. All three
samples were below the detection limit.
Post P' Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit. Since all of the
samples were below the detection limits after the first cleaning, no additional samples were
collected for cristobalite.