Tridymite Before Cleaning Samples - There were three pre-cleaning wipe samples collected. All three samples were below the detection limit.

Post P' Cleaning Samples - There were two air samples and four wipe samples collected after the first cleaning. All of the samples were below the detection limit. Since all of the samples were below the detection limits after the first cleaning, no additional samples were collected for tridymite.

MMVF Before Cleaning Samples - There were three pre-cleaning wipe samples collected. All three of the samples had MMVF detected.

Post P' Cleaning Samples - There were three air samples and five wipe samples collected after the first cleaning. The results for the three air samples indicate that MMVF was present; however, all samples were below the numeric criterion of 10 S/L. The results of the five wipe samples indicate that MMVF was still present in all of five of the samples after the first cleaning, however the concentrations detected were lower than the pre-cleaning samples. This indicates the cleaning techniques were effective at reducing the pre-cleaning concentrations of MMVF.

PAHs Before Cleaning Samples - There were three pre-cleaning wipe samples collected. All three samples were below the detection limit and the TEF for each sample was below the numeric criterion.

Post Cleaning Samples - There were four wipe samples collected after the first cleaning. All of the samples were below the detection limit and the TEF for each sample was below the numeric criterion of 300 p-g/m^. Since all of the samples were below the detection limit and the numeric criterion after the first cleaning, no additional samples were collected for PAHs.

Total Dust Before Cleaning Samples - There were three pre-cleaning wipe samples collected; however, EPA only requested to have two of the samples analyzed. The results indicate that there was dust present.

Post P' Cleaning Samples - There were four wipe samples collected after the first cleaning; however, EPA only requested to have two of the samples analyzed. Both samples indicate that dust was present at higher concentrations than the pre-cleaning concentration.

74

CITY_21MC100_004205030

NYC-WTC_000276726

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276726Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →