Numeric Criteria - This unit met the numeric criteria listed in Table 1 for each compound
after being cleaned twice.
Asbestos
Before Cleaning Samples - Pre-cleaning micro vacuum and wipe samples were collected for
asbestos. These samples indicate that asbestos was present in the unit prior to cleaning.
Chrysotile was detected in six of the seven micro vacuum samples and all four of the wipe
samples; however, chrysotile was present below the detection limit in two of the four wipe
samples.
Post Cleaning — There were post-cleaning air, micro vacuum, and wipe samples collected.
The three air samples were analyzed using PCM and TEM PCMe. The PCM results were all
below the secondary numeric criterion of 0.01 f/cc. All three TEM PCMe analysis were
below the primary criterion of 0.0009 S/cc and not detected in two of those samples.
The results for the seven micro vacuum samples indicate that asbestos was present in most
samples at levels generally lower than those observed before cleaning.
The results for the five wipe samples that were collected indicate that asbestos was present in
one sample; however, all samples were below the detection limit. The results indicate that
the cleaning techniques used were effective in reducing the asbestos concentrations observed
prior to cleaning.
Dioxin
Before Cleaning Samples - There were three pre-cleaning wipe samples collected and
analyzed for dioxin. The results indicate that there was dioxin present; however, the TEQ
concentration for each sample was below the primary numeric criterion of 4 ng/m^.
Post P' Cleaning Samples - There were four post-cleaning wipe samples collected and
analyzed for dioxin. The results indicate that the TEQ concentration for each sample was
below the primary numeric criterion of 4 ng/m^.
Gypsum
Before Cleaning Samples - There were three pre-cleaning wipe samples collected. The
results indicate that gypsum was not detected.
Post P' Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. The results indicate that gypsum was not detected in any sample.
Lead
Before Cleaning Samples - There were seven micro vacuum samples and three wipe samples
collected. The results indicate that lead was detected in one of the seven micro vacuum
72