Post P' Cleaning Samples - There were two air samples, four micro vacuum samples, and
four wipe samples collected after the first cleaning. The two air samples were below the
numeric criteria but were qualified as rejected due to field blank contamination. The results
of the micro vacuum and wipe samples show that, while two of the micro vacuum and two of
the wipes samples exceeded the detection limits, all samples met the numeric criterion for
lead after the first cleaning.
Alpha Quartz
Before Cleaning Samples - There were three pre-cleaning wipe samples collected. Two of
the three samples were below the detection limit and the third sample had alpha-quartz
detected.
Post P' Cleaning Samples - There were two air and four wipe samples collected after the first
cleaning. All samples were below the detection limit.
Calcite
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. All four
samples were below the detection limit.
Post P' Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit.
Cristobalite
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. All four
samples were below the detection limit.
Post P' Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit.
Tridymite
Before Cleaning Samples - There were four pre-cleaning wipe samples collected. All four
samples were below the detection limit.
Post Cleaning Samples - There were two air samples and four wipe samples collected
after the first cleaning. All of the samples were below the detection limit
MMVF
Before Cleaning Samples - There were two pre-cleaning air samples and three pre-cleaning
wipe samples collected. The two air samples had MMVF detected, but below the numeric
criterion. The three wipe samples had MMVF detected in concentrations from 57.23 S/cc to
801.24 S/cc; however, there is not an established criterion for MMVF in settled dust.