NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 121 pages

COPCS report, NYC WTC chain of custody

Machine-extracted title · confidence 50%

Table of contents for contaminants of [name] report and building sections.

NYC-WTC_000276652–000276772
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

INTERNAL REVIEW DRAFT z-s Post P' Cleaning Samples - There were two air samples, four micro vacuum samples, and four wipe samples collected after the first cleaning. The two air samples were below the numeric criteria but were qualified as rejected due to field blank contamination. The results of the micro vacuum and wipe samples show that, while two of the micro vacuum and two of the wipes samples exceeded the detection limits, all samples met the numeric criterion for lead after the first cleaning.

Alpha Quartz Before Cleaning Samples - There were three pre-cleaning wipe samples collected. Two of the three samples were below the detection limit and the third sample had alpha-quartz detected.

Post P' Cleaning Samples - There were two air and four wipe samples collected after the first cleaning. All samples were below the detection limit.

Calcite Before Cleaning Samples - There were four pre-cleaning wipe samples collected. All four samples were below the detection limit.

Post P' Cleaning Samples - There were two air samples and four wipe samples collected after the first cleaning. All of the samples were below the detection limit.

Cristobalite Before Cleaning Samples - There were four pre-cleaning wipe samples collected. All four samples were below the detection limit.

Post P' Cleaning Samples - There were two air samples and four wipe samples collected after the first cleaning. All of the samples were below the detection limit.

Tridymite Before Cleaning Samples - There were four pre-cleaning wipe samples collected. All four samples were below the detection limit.

Post Cleaning Samples - There were two air samples and four wipe samples collected after the first cleaning. All of the samples were below the detection limit

MMVF Before Cleaning Samples - There were two pre-cleaning air samples and three pre-cleaning wipe samples collected. The two air samples had MMVF detected, but below the numeric criterion. The three wipe samples had MMVF detected in concentrations from 57.23 S/cc to 801.24 S/cc; however, there is not an established criterion for MMVF in settled dust.

41

CITY_21MC100_004204997

NYC-WTC_000276693

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276693Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →