NYC 9/11 Public Portal Document

INTERNAL REVIEW DRAFT

and TEM PCMe. The PCM results indicate that one sample was below the secondary numeric criterion and the other two could not be analyzed due to particulate overloading of the filter. The TEM AHERA results were below the secondary numeric criterion for two samples. The third sample could not be analyzed due to particulate overloading of the filter. Of the three air samples analyzed using TEM PCMe, one sample could not be analyzed due to overloading of particulate material and the other two samples were below the primary numeric criteria of 0.0009 S/cc.

The results of the four micro vacuum samples indicate that asbestos was present at levels generally lower than those observed before cleaning, and one of the samples was identified as non-detect.

The results of the five wipe samples indicate that asbestos was present in three samples. The other two samples were identified as non-detect. One of the non-detect samples had an elevated detection limit due to the presence of non-asbestos particulate matter.

Dioxin Before Cleaning Samples - There were three pre-cleaning wipe samples collected and analyzed for dioxin. The results indicate that there was dioxin present; however, the TEQ concentrations for each sample were below the numeric criterion of 4 ng/'mf

Post Cleaning Samples - There were four post-cleaning wipe samples collected and analyzed for dioxin. The results indicate that the concentrations of dioxin detected were similar to the pre-cleaning samples and the TEQ concentrations for each sample were below the criterion of 4 nghnY

Gypsum Before Cleaning Samples - There were three pre-cleaning wipe samples collected. The results indicate gypsum was not detected above the detection limit. It should be noted that the detection limit ranged from 1 to 10 mg/m^.

Post P' Cleaning Samples - There were two air samples and four wipe samples collected after the first cleaning. The results indicate that gypsum was not detected above the detection limit for the air samples, and not detected above the detection limit for wipe samples.

Lead Before Cleaning Samples - There were four micro vacuum samples and three wipe samples collected. The results indicate that lead was not detected in any of the micro vacuum samples. One of the wipe samples was below the detection limit and one wipe sample was below primary numeric criteria of 25 pg/ftf The third wipe sample exceeded the primary numeric criteria at 38.9 pg/fF.

40

CITY_21MC100_004204996

NYC-WTC_000276692

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276692Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →