MMVF
Before Cleaning Samples - There were no before cleaning samples collected.
Post J" Cleaning Samples - There were two air samples collected after the first cleaning.
The results indicate that MMVF was present in one of the samples; however, the
concentration was below the numeric criterion of 10 S/L. Since the air samples were below
the numeric criterion, no additional samples were collected for MMVF.
PAHs
Before Cleaning Samples - There were no before cleaning samples collected.
Post P' Cleaning Samples - There were no post-first cleaning samples collected.
Total Dust
Before Cleaning Samples - There were no before cleaning samples collected.
Post J" Cleaning Samples - There were no post-first cleaning samples collected.
Unit 3A - This is a 1,368 sq. ft. loft which faces Cedar Street and is utilized as office space for
Baldwin Realty. Carpet is present on half the floor space, the remainder is hardwood floors. No
windows were blown in, the area is furnished with 10-12 wooden desks, files and office equipment.
There was minimal dust accumulation in dwelling.
Cleaning Method - This unit was cleaned using test method 2B. Test method 2B used a
Craftsman shop vacuum and Eureka upright with HEPA for vacuuming the floors and other
surfaces. An AFD was used during the cleaning process. In addition, all horizontal surfaces
were wet wiped.
Numeric Criteria - This unit met the numeric criteria listed in Table 1 for each compound
after being cleaned once.
Asbestos
Before cleaning samples - Pre-cleaning micro vacuum, wipe and air samples were collected
for asbestos. These samples indicate that asbestos was present in the unit prior to cleaning.
All four of the micro vacuum samples detected chrysotile, one of the four wipe samples
detected chrysotile, the PCM results for both air samples were below the secondary numeric
criterion, and the two TEM PCMe air results were below the primary numeric criteria of
0.0009 S/cc.
Post P' Cleaning Samples - Post-cleaning micro vacuum, wipe and air samples were
collected for asbestos. Tliree asbestos air samples were analyzed for PCM, TEM AHERA,
39